First UK trial of Xenex PX-UV, an automated ultraviolet room decontamination device in a clinical haematology and bone marrow transplantation unit.
Beal, A; Mahida, N; Staniforth, K; Vaughan, N; Clarke, M; Boswell, T.
Afiliação
  • Beal A; Infection Prevention and Control Department, Nottingham University Hospitals NHS Trust, Nottingham, UK.
  • Mahida N; Department of Clinical Microbiology, Nottingham University Hospitals NHS Trust, Nottingham, UK.
  • Staniforth K; Infection Prevention and Control Department, Nottingham University Hospitals NHS Trust, Nottingham, UK.
  • Vaughan N; Infection Prevention and Control Department, Nottingham University Hospitals NHS Trust, Nottingham, UK.
  • Clarke M; Infection Prevention and Control Department, Nottingham University Hospitals NHS Trust, Nottingham, UK.
  • Boswell T; Department of Clinical Microbiology, Nottingham University Hospitals NHS Trust, Nottingham, UK. Electronic address: tim.boswell@nuh.nhs.uk.
J Hosp Infect ; 93(2): 164-8, 2016 Jun.
Article em En | MEDLINE | ID: mdl-27107618
ABSTRACT

BACKGROUND:

There is growing interest in the use of no-touch automated room decontamination devices within healthcare settings. Xenex PX-UV is an automated room disinfection device using pulsed ultraviolet (UV) C radiation with a short cycle time.

AIM:

To investigate the microbiological efficacy of this device when deployed for terminal decontamination of isolation rooms within a clinical haematology unit.

METHODS:

The device was deployed in isolation rooms in a clinical haematology unit. Contact plates were applied to common touch points to determine aerobic total colony counts (TCCs) and samples collected using Polywipe™ sponges for detection of vancomycin-resistant enterococci (VRE).

FINDINGS:

The device was easy to transport, easy to use, and it disinfected rooms rapidly. There was a 76% reduction in the TCCs following manual cleaning, with an additional 14% reduction following UV disinfection, resulting in an overall reduction of 90% in TCCs. There was a 38% reduction in the number of sites where VRE was detected, from 26 of 80 sites following manual cleaning to 16 of 80 sites with additional UV disinfection.

CONCLUSIONS:

The Xenex PX-UV device can offer a simple and rapid additional decontamination step for terminal disinfection of patient rooms. However, the microbiological efficacy against VRE was somewhat limited.