XAS spectroelectrochemistry: reliable measurement of X-ray absorption spectra from redox manipulated solutions at room temperature.
Best, Stephen P; Levina, Aviva; Glover, Chris; Johannessen, Bernt; Kappen, Peter; Lay, Peter A.
Afiliação
  • Best SP; School of Chemistry, University of Melbourne, Parkville, Melbourne, Victoria 3010, Australia.
  • Levina A; School of Chemistry, The University of Sydney, Sydney, New South Wales 2006, Australia.
  • Glover C; Australian Synchrotron, 800 Blackburn Road, Clayton, Victoria 3168, Australia.
  • Johannessen B; Australian Synchrotron, 800 Blackburn Road, Clayton, Victoria 3168, Australia.
  • Kappen P; Australian Synchrotron, 800 Blackburn Road, Clayton, Victoria 3168, Australia.
  • Lay PA; School of Chemistry, The University of Sydney, Sydney, New South Wales 2006, Australia.
J Synchrotron Radiat ; 23(Pt 3): 743-50, 2016 05.
Article em En | MEDLINE | ID: mdl-27140154
ABSTRACT
The design and operation of a low-volume spectroelectrochemical cell for X-ray absorption spectroscopy (XAS) of solutions at room temperature is described. Fluorescence XAS measurements are obtained from samples contained in the void space of a 50 µL reticulated vitreous carbon (sponge) working electrode. Both rapid electrosynthesis and control of the effects of photoreduction are achieved by control over the flow properties of the solution through the working electrode, where a good balance between the rate of consumption of sample and the minimization of decomposition was obtained by pulsing the flow of the solution by 1-2 µL with duty cycle of ∼3 s while maintaining a small net flow rate (26-100 µL h(-1)). The performance of the cell in terms of control of the redox state of the sample and minimization of the effects of photoreduction was demonstrated by XAS measurements of aqueous solutions of the photosensitive Fe(III) species, [Fe(C2O4)3](3-), together with that of the electrogenerated [Fe(C2O4)3](4-) product. The current response from the cell during the collection of XAS spectra provides an independent measure of the stability of the sample of the measurement. The suitability of the approach for the study of small volumes of mM concentrations of protein samples was demonstrated by the measurement of the oxidized and electrochemically reduced forms of cytochrome c.