Your browser doesn't support javascript.
loading
The high matrix acquisition technique for imaging of atherosclerotic plaque inflammation in fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography with time-of-flight: Phantom study.
Suda, Masaya; Kiriyama, Tomonari; Ishihara, Keiichi; Onoguchi, Masahisa; Kobayashi, Yasuhiro; Sakurai, Minoru; Shibutani, Takayuki; Kumita, Shin-Ichiro.
Afiliação
  • Suda M; Clinical Imaging Center for Healthcare, Nippon Medical School, 1-12-15, Sendagi, Bunkyo, Tokyo, 113-0022, Japan. msuda@nms.ac.jp.
  • Kiriyama T; Department of Radiology, Nippon Medical School, Tokyo, Japan.
  • Ishihara K; Clinical Imaging Center for Healthcare, Nippon Medical School, 1-12-15, Sendagi, Bunkyo, Tokyo, 113-0022, Japan.
  • Onoguchi M; Department of Quantum Medical Technology, Kanazawa University, Kanazawa, Japan.
  • Kobayashi Y; Department of Radiology, Nippon Medical School, Tokyo, Japan.
  • Sakurai M; Clinical Imaging Center for Healthcare, Nippon Medical School, 1-12-15, Sendagi, Bunkyo, Tokyo, 113-0022, Japan.
  • Shibutani T; Department of Quantum Medical Technology, Kanazawa University, Kanazawa, Japan.
  • Kumita SI; Department of Radiology, Nippon Medical School, Tokyo, Japan.
J Nucl Cardiol ; 24(4): 1161-1170, 2017 08.
Article em En | MEDLINE | ID: mdl-27197819
ABSTRACT

BACKGROUND:

Motion artifact and partial volume effect caused underestimation of coronary plaque inflammation. This study evaluated the high matrix acquisition technique using time-of-flight (TOF) positron emission tomography/computed tomography for imaging of atherosclerotic plaque inflammation with fluorine-18 fluorodeoxyglucose in small and moving phantoms. METHODS AND

RESULTS:

All images were reconstructed using a conventional algorithm without TOF (4 × 4 × 4 mm3 voxel size) and a high matrix algorithm with TOF (2 × 2 × 2 mm3 voxel size). Microsphere phantoms of 10, 7.9, 6.2, 5.0, and 4.0 mm diameters were acquired in 3-dimensional list-mode for 30 minutes. A heart phantom mimicking cardiac motion consisted of a hot spot simulating a plaque (φ 4 mm, φ 2 mm) on the outside of the left ventricle. In the microsphere and heart phantom study, visual discrimination, maximum activity, and target-to-background ratio using the high matrix algorithm with TOF were better than those using the conventional algorithm without TOF.

CONCLUSION:

The high matrix algorithm with TOF improves detection of small targets in phantoms.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imagens de Fantasmas / Fluordesoxiglucose F18 / Placa Aterosclerótica / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada / Inflamação Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Imagens de Fantasmas / Fluordesoxiglucose F18 / Placa Aterosclerótica / Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada / Inflamação Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article