Your browser doesn't support javascript.
loading
Strain sonoelastographic evaluation of biceps muscle intrinsic stiffness after botulinum toxin-A injection.
Askin, Ayhan; Kalayci, Özlem Tugçe; Bayram, Korhan Baris; Tosun, Aliye; Demirdal, Ümit Seçil; Atar, Emel; Inci, Mehmet Fatih.
Afiliação
  • Askin A; a Department of Physical Medicine and Rehabilitation , Katip Celebi University Ataturk Training and Research Hospital , Izmir , Turkey.
  • Kalayci ÖT; b Department of Radiology , Katip Celebi University Ataturk Training and Research Hospital , Izmir , Turkey.
  • Bayram KB; a Department of Physical Medicine and Rehabilitation , Katip Celebi University Ataturk Training and Research Hospital , Izmir , Turkey.
  • Tosun A; a Department of Physical Medicine and Rehabilitation , Katip Celebi University Ataturk Training and Research Hospital , Izmir , Turkey.
  • Demirdal ÜS; a Department of Physical Medicine and Rehabilitation , Katip Celebi University Ataturk Training and Research Hospital , Izmir , Turkey.
  • Atar E; a Department of Physical Medicine and Rehabilitation , Katip Celebi University Ataturk Training and Research Hospital , Izmir , Turkey.
  • Inci MF; b Department of Radiology , Katip Celebi University Ataturk Training and Research Hospital , Izmir , Turkey.
Top Stroke Rehabil ; 24(1): 12-17, 2017 01.
Article em En | MEDLINE | ID: mdl-27211845
ABSTRACT

BACKGROUND:

The most commonly used clinical tools for measuring spasticity are modified Ashworth scale (MAS) and Tardieu scale but both yield subjective rather than objective results. Ultrasound elastography (EUS) provides information on tissue stiffness and allows the qualitative or quantitative measurements of the mechanical properties of tissues.

OBJECTIVE:

To assess the stiffness of biceps brachialis muscles in stroke patients by strain EUS and to investigate the sonoelastographic changes and its correlations with clinical evaluation parameters after botulinum toxin-A (BTA) injections.

METHODS:

This is a prospective study. A total of 48 chronic stroke patients requiring BTA injections to biceps brachialis muscles were included in the study. All patients received injections with BTA to biceps brachialis muscles under ultrasound guidance. MAS, goniometric measurements, and strain EUS assessments were performed at preintervention and at 4-week postintervention.

RESULTS:

Strain index values of biceps muscle on the affected side were significantly increased compared with those on the unaffected side (p < 0.01). At 4 weeks after BTA injection, significant improvements were observed in MAS grades and goniometric measurements (p < 0.05). Statistically significant differences were also found between the MAS grades and strain index values in both pre-/postintervention period (p < 0.01). No significant correlations were observed between clinical parameters and strain EUS findings.

CONCLUSIONS:

Strain EUS is a promising diagnostic tool for assessing stiffness in spastic muscles, in establishing the treatment plan and monitoring the effectiveness of the therapeutic modality.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Músculo Esquelético / Toxinas Botulínicas Tipo A / Acidente Vascular Cerebral / Técnicas de Imagem por Elasticidade / Fármacos Neuromusculares Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Qualitative_research Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Músculo Esquelético / Toxinas Botulínicas Tipo A / Acidente Vascular Cerebral / Técnicas de Imagem por Elasticidade / Fármacos Neuromusculares Tipo de estudo: Diagnostic_studies / Guideline / Observational_studies / Qualitative_research Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article