Your browser doesn't support javascript.
loading
[(123)I]-Ioflupane SPECT in combination with MIBG myocardial scintigraphy in Parkinson's disease: a case series study.
Yamada, Akane; Murakami, Takenobu; Kang, Yongjin; Iikuni, Yoichiro; Morimatsu, Akeshi; Shirata, Akiko; Ito, Hiroshi; Ugawa, Yoshikazu; Yamane, Kiyomi.
Afiliação
  • Yamada A; Department of Neurology, Neurological Institute, Ohta-Atami Hospital.
Rinsho Shinkeigaku ; 56(6): 400-6, 2016 06 22.
Article em Ja | MEDLINE | ID: mdl-27212677
ABSTRACT
Metaiodobenzylguanidine (MIBG) myocardial scintigraphy is widely accepted as a beneficial tool for differentiating Parkinson's disease (PD) from other Parkinson-related disorders (PRD). In Japan, dopamine transporter (DAT) imaging, which can evaluate presynaptic degeneration of dopamine neurons, has been applied in clinics since 2014. The present study investigated the utility of [(123)I]-Ioflupane single photon emission computed tomography (SPECT) combined with MIBG myocardial scintigraphy for the diagnosis of PD. We performed [(123)I]-Ioflupane SPECT and MIBG myocardial scintigraphy in 63 PD patients, 8 PRD patients and 1 essential tremor patient, and obtained the specific binding ratio (SBR [cut-off 4.5]) and the heart-to-mediastinum ratio (H/M [cut-off 2.2]). In 70% of the PD patients, both parameters were significantly reduced. In 22% of the PD patients, the SBR was smaller than 4.5 with normal H/M, and H/M was less than 2.2 with normal SBR in 5% of all subjects. Either the SBR or H/M was significantly reduced in 97% of the study population. The SBR showed low disease specificity to PD (11%), and the SBR and H/M negatively correlated with disease duration. These findings indicate that [(123)I]-Ioflupane SPECT combined with MIBG myocardial scintigraphy can improve the detection rate of PD. However, careful interpretation of these results is required because [(123)I]-Ioflupane SPECT poorly differentiates PD from PRD. Progression of PD may reflect the gradual reduction of isotope accumulation, hence, both [(123)I]-Ioflupane SPECT and MIBG myocardial scintigraphy should be tested repeatedly even in clinically suspected PD cases showing negative results.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença de Parkinson / Tomografia Computadorizada de Emissão de Fóton Único / Compostos Radiofarmacêuticos / 3-Iodobenzilguanidina / Imagem de Perfusão do Miocárdio / Coração / Radioisótopos do Iodo / Nortropanos Tipo de estudo: Diagnostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: Ja Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Doença de Parkinson / Tomografia Computadorizada de Emissão de Fóton Único / Compostos Radiofarmacêuticos / 3-Iodobenzilguanidina / Imagem de Perfusão do Miocárdio / Coração / Radioisótopos do Iodo / Nortropanos Tipo de estudo: Diagnostic_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: Ja Ano de publicação: 2016 Tipo de documento: Article