BACKGROUND:

Low back pain and degeneration of the intervertebral disc are an integrated malady that affects millions of Americans. Cage devices used in association with posterior lumbar interbody fusion (PLIF) have been shown to be an effective approach in the treatment of a number of lower spine disorders attributed to degenerative disc disease (DDD).

OBJECTIVE:

This study was undertaken as part of a U.S. Food and Drug Administration (FDA) Investigational Device Exemption (IDE) study and compares the effectiveness of the Asfora Bullet Cage System (ABCS) to successfully fuse vertebra at one or two levels between L2 and S1 in patients with DDD to an FDA approved comparison device, the Medtronic-Sofamor Danek Inter Fix Threaded Fusion Device (MSDIFD).

METHODS:

A total of 257 randomized participants were implanted with either the ABCS device (n = 132) or the MSDIFD device (n = 125) through an open posterior approach using autogenous local bone graft without the use of pedicle screws. Patients were evaluated prior to surgery and at the 24 month (24-M) visit for fusion status, deep tendon reflex status, sensory function, motor function, straight leg raise status, pain, disability, and device safety. Radiological evaluation and statistical analysis were performed by independent professionals.

RESULTS:

Evaluation of device success was performed at 24-M visit. From the original group of 257 patients, 59 were lost to follow-up. Primary measures of success at the 24-M visit involved pain and function, fusion, neurological status, and device-related adverse events measures. Pain and function improved in both (MSDIFD 75.7 percent; ABCS 82.6 percent). Fusion success with all radiographic points at 24-M visits was 79.4 percent MSDIFD and 88.2 percent ABCS. Neurological improvement was seen in both (MSDIFD 77.0 percent; ABCS 87.8 percent). One device-related grade 1 adverse event was reported in the MSDIFD group. Disc height preservation was equivalent for single level fusions (MSDIFD 16.1 percent; ABCS 20.0 percent) and second level fusions (MSDIFD 10.7 percent; ABCS 14.3 percent). General health and well-being improvement was the same (MSDIFD 37.0 percent; ABCS 40.0 percent). Subsequent fusion, up to 10 years, was equivalent (MSDIFD 83.8 percent; ABCS 91.2). Results for both devices were considered to be satisfactory, with a slight non-significant superiority for the ABCS.

CONCLUSION:

From the ABCS device FDA IDE sanctioned study and the review of the literature, we concluded that the Asfora Bullet Cage System is safe, effective and comparable to other interbody fusion devices which are used stand-alone or in conjunction with pedicle screws, rhBMP-2, or autogenous bone harvested from the iliac crest inserted through anterior, lateral or posterior approaches.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Fixação Ortopédica / Fusão Vertebral / Dor Lombar / Degeneração do Disco Intervertebral / Vértebras Lombares Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2016 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Dispositivos de Fixação Ortopédica / Fusão Vertebral / Dor Lombar / Degeneração do Disco Intervertebral / Vértebras Lombares Tipo de estudo: Clinical_trials / Diagnostic_studies Limite: Adolescent / Adult / Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do norte Idioma: En Ano de publicação: 2016 Tipo de documento: Article