Your browser doesn't support javascript.
loading
Comparison of the accuracy of intraocular lens power calculations for cataract surgery in eyes after phototherapeutic keratectomy.
Yaguchi, Yukari; Negishi, Kazuno; Saiki, Megumi; Torii, Hidemasa; Tsubota, Kazuo.
Afiliação
  • Yaguchi Y; Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
  • Negishi K; Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan. fwic7788@mb.infoweb.ne.jp.
  • Saiki M; Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
  • Torii H; Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
  • Tsubota K; Department of Ophthalmology, Keio University School of Medicine, 35 Shinanomachi, Shinjuku-ku, Tokyo, 160-8582, Japan.
Jpn J Ophthalmol ; 60(5): 365-72, 2016 Sep.
Article em En | MEDLINE | ID: mdl-27277426
PURPOSE: To compare the accuracy of several methods of intraocular lens (IOL) power calculations used for cataract surgery in eyes treated with phototherapeutic keratectomy (PTK) that results in changes in the anterior corneal surface and axial length; these results make power calculations less predictable. METHODS: We evaluated the medical records of 23 eyes of 13 patients (mean age, 68.8 years; range 62-80 years) who underwent cataract surgery after PTK at Keio University Hospital, Tokyo, Japan. The prediction error, defined as the difference between the estimated postoperative spherical equivalent and the postoperative manifest refraction at the spectacle plane, was calculated using five formulas: SRK/T, Haigis-L, Shammas-PL, Camellin-Calossi, and OKULIX ray tracing software. We compared the median values of the arithmetic and absolute prediction errors among the five formulas. RESULTS: The median arithmetic errors after cataract surgery for the five formulas were 0.70 D (diopter) (range -0.41 to 2.78), -0.96 D (range -2.14 to 0.81), -0.81 D (range -1.89 to 1.15), -0.04 D (range -1.35 to 1.47), and 0.68 D (range -0.61 to 2.50), respectively. CONCLUSION: The Camellin-Calossi formula is a good option for calculating IOL powers in eyes that underwent PTK.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Catarata / Extração de Catarata / Distrofias Hereditárias da Córnea / Ceratectomia Fotorrefrativa / Lentes Intraoculares Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Humans / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Refração Ocular / Catarata / Extração de Catarata / Distrofias Hereditárias da Córnea / Ceratectomia Fotorrefrativa / Lentes Intraoculares Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged / Aged80 / Humans / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article