Added value of diffusion-weighted magnetic resonance imaging for the detection of pancreatic fluid collection infection.
Borens, Bruno; Arvanitakis, Marianna; Absil, Julie; El Bouchaibi, Saïd; Matos, Celso; Eisendrath, Pierre; Toussaint, Emmanuel; Deviere, Jacques; Bali, Maria Antonietta.
Afiliação
  • Borens B; Polyclinique Santa Maria, 57, Avenue de la Californie, 06200, Nice, France. bb@docteur-borens.com.
  • Arvanitakis M; Department of Gastroenterology, Erasme Hospital, 808 Route de Lennik, 1070, Brussels, Belgium.
  • Absil J; Department of Radiology, Erasme Hospital, 808 Route de Lennik, 1070, Brussels, Belgium.
  • El Bouchaibi S; Epicura, 1 Rue Maria Thomée, 7800, Ath, Belgium.
  • Matos C; Department of Radiology, Erasme Hospital, 808 Route de Lennik, 1070, Brussels, Belgium.
  • Eisendrath P; Department of Gastroenterology, Erasme Hospital, 808 Route de Lennik, 1070, Brussels, Belgium.
  • Toussaint E; Department of Gastroenterology, Erasme Hospital, 808 Route de Lennik, 1070, Brussels, Belgium.
  • Deviere J; Department of Gastroenterology, Erasme Hospital, 808 Route de Lennik, 1070, Brussels, Belgium.
  • Bali MA; Department of Radiology, Erasme Hospital, 808 Route de Lennik, 1070, Brussels, Belgium.
Eur Radiol ; 27(3): 1064-1073, 2017 Mar.
Article em En | MEDLINE | ID: mdl-27300193
ABSTRACT

OBJECTIVES:

To investigate the added value of diffusion-weighted (DW) magnetic resonance (MR) imaging in the detection of infection in pancreatic fluid collections (PFC).

METHODS:

Forty-patients with PFC requiring endoscopic-transmural drainage underwent conventional-MR and DW-MR imaging (b = 1000 s/mm2) before endoscopy. MR images were divided into two sets (set1, conventional-MR; set2, conventional-MR, DW-MR and ADC maps) and randomized. Two independent readers performed qualitative and quantitative (apparent diffusion coefficient, ADC) image analysis. Bacteriological analysis of PFC content was the gold standard. Non-parametric tests were used for comparisons. Sensitivity, specificity, negative predictive value (NPV), positive predictive value (PPV) and accuracy were calculated for the two sets for both readers. Receiver operating characteristic curves (ROC) were drawn to assess quantitative DW-MR imaging diagnostic performance.

RESULTS:

For both readers, sensitivity, specificity, NPV, PPV and accuracy for infected PFCs were higher for set2 (P > .05). ADC were lower in infected versus non-infected PFCs (P ≤ .031). Minimum ADC cut-off 1,090×10-3 mm2/s for reader 1 and 1,012×10-3 mm2/s for reader 2 (sensitivity and specificity 67 % and 96 % for both readers).

CONCLUSION:

Qualitative information provided by DW-MR may help to assess PFCs infection. Infected PFCs show significantly lower ADCs compared to non-infected ones. KEY POINTS • DW improves MR diagnostic accuracy to detect infection of PFC • Infected PFCs show lower ADC compared to non-infected ones (P < .031) • DW-MR images are easy to interpret especially for non-experienced radiologist.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pancreatopatias / Suco Pancreático / Infecções Bacterianas / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pancreatopatias / Suco Pancreático / Infecções Bacterianas / Imagem de Difusão por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Qualitative_research / Risk_factors_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article