Your browser doesn't support javascript.
loading
Comparison of the impact of the Tobacco Heating System 2.2 and a cigarette on indoor air quality.
Mitova, Maya I; Campelos, Pedro B; Goujon-Ginglinger, Catherine G; Maeder, Serge; Mottier, Nicolas; Rouget, Emmanuel G R; Tharin, Manuel; Tricker, Anthony R.
Afiliação
  • Mitova MI; Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland (part of Philip Morris International group of companies). Electronic address: maya.mitova@pmi.com.
  • Campelos PB; Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland (part of Philip Morris International group of companies).
  • Goujon-Ginglinger CG; Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland (part of Philip Morris International group of companies).
  • Maeder S; Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland (part of Philip Morris International group of companies).
  • Mottier N; Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland (part of Philip Morris International group of companies).
  • Rouget EG; Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland (part of Philip Morris International group of companies).
  • Tharin M; Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland (part of Philip Morris International group of companies).
  • Tricker AR; Philip Morris International R&D, Philip Morris Products S.A., Quai Jeanrenaud 5, 2000 Neuchâtel, Switzerland (part of Philip Morris International group of companies).
Regul Toxicol Pharmacol ; 80: 91-101, 2016 Oct.
Article em En | MEDLINE | ID: mdl-27311683
ABSTRACT
The impact of the Tobacco Heating System 2.2 (THS 2.2) on indoor air quality was evaluated in an environmentally controlled room using ventilation conditions recommended for simulating "Office", "Residential" and "Hospitality" environments and was compared with smoking a lit-end cigarette (Marlboro Gold) under identical experimental conditions. The concentrations of eighteen indoor air constituents (respirable suspended particles (RSP) < 2.5 µm in diameter), ultraviolet particulate matter (UVPM), fluorescent particulate matter (FPM), solanesol, 3-ethenylpyridine, nicotine, 1,3-butadiene, acrylonitrile, benzene, isoprene, toluene, acetaldehyde, acrolein, crotonaldehyde, formaldehyde, carbon monoxide, nitrogen oxide, and combined oxides of nitrogen) were measured. In simulations evaluating THS 2.2, the concentrations of most studied analytes did not exceed the background concentrations determined when non-smoking panelists were present in the environmentally controlled room under equivalent conditions. Only acetaldehyde and nicotine concentrations were increased above background concentrations in the "Office" (3.65 and 1.10 µg/m(3)), "Residential" (5.09 and 1.81 µg/m(3)) and "Hospitality" (1.40 and 0.66 µg/m(3)) simulations, respectively. Smoking Marlboro Gold resulted in greater increases in the concentrations of acetaldehyde (58.8, 83.8 and 33.1 µg/m(3)) and nicotine (34.7, 29.1 and 34.6 µg/m(3)) as well as all other measured indoor air constituents in the "Office", "Residential" and "Hospitality" simulations, respectively.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição por Fumaça de Tabaco / Fumar / Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Exposição por Inalação / Poluentes Atmosféricos / Equipamentos e Provisões Elétricas Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Adult / Humans / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluição por Fumaça de Tabaco / Fumar / Monitoramento Ambiental / Poluição do Ar em Ambientes Fechados / Exposição por Inalação / Poluentes Atmosféricos / Equipamentos e Provisões Elétricas Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Adult / Humans / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article