Your browser doesn't support javascript.
loading
Comparison between different software programs and post-processing techniques for the MRI quantification of liver iron concentration in thalassemia patients.
Bacigalupo, Lorenzo; Paparo, Francesco; Zefiro, Daniele; Viberti, Carlo Maria; Cevasco, Luca; Gianesin, Barbara; Pinto, Valeria Maria; Rollandi, Gian Andrea; Wood, John C; Forni, Gian Luca.
Afiliação
  • Bacigalupo L; Radiology Unit, Department of Diagnostic Imaging, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128, Genoa, Italy. lorenzo.bacigalupo@galliera.it.
  • Paparo F; Radiology Unit, Department of Diagnostic Imaging, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128, Genoa, Italy.
  • Zefiro D; Department of Medical Physics, ASL n.5 "Spezzino", Via XXIV Maggio 139, 19124, La Spezia, Italy.
  • Viberti CM; Medical Physics Unit, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128, Genoa, Italy.
  • Cevasco L; Radiology Unit, Department of Diagnostic Imaging, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128, Genoa, Italy.
  • Gianesin B; Medical Physics Unit, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128, Genoa, Italy.
  • Pinto VM; Microcitemia and Hereditary Anaemias Unit, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128, Genoa, Italy.
  • Rollandi GA; Radiology Unit, Department of Diagnostic Imaging, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128, Genoa, Italy.
  • Wood JC; Department of Radiology, Children's Hospital Los Angeles, Los Angeles, CA, USA.
  • Forni GL; Microcitemia and Hereditary Anaemias Unit, E.O. Ospedali Galliera, Mura delle Cappuccine 14, 16128, Genoa, Italy.
Radiol Med ; 121(10): 751-62, 2016 Oct.
Article em En | MEDLINE | ID: mdl-27334009
PURPOSE: In magnetic resonance imaging (MRI) relaxometry, various software programs are available to perform R2* measurements and to estimate the liver iron concentration (LIC). The main objective of our study was to compare R2* LIC values, obtained with three different software programs based on specific decay models and calibration curves, with LIC estimates provided by R2-relaxometry (FerriScan). METHODS: This retrospective study included 15 patients with 15 baseline MRIs and 34 serial examinations. R2* LIC estimates were calculated using the FuncTool, CMRtools/Thalassemia Tools and Quanta Hematology programs. Longitudinal LIC changes (ΔLIC) were calculated using the subset of 34 serial MRIs. RESULTS: After Bland-Altman analysis on baseline data, Quanta Hematology, which employs the monoexponential-plus-constant fit, produced the lowest mean difference [0.01 ± 0.14 log(mg/gdw)] with the closest limits of agreement. In the longitudinal setting, Quanta Hematology again gave the lowest mean difference between R2 and R2* LIC (0.1 ± 2.6 mg/gdw). Using FerriScan as reference, the value of concordant directional ΔLIC changes was the same for all programs (27/34, 85.7 %). CONCLUSIONS: R2* LICs are higher than R2 LICs at iron levels <7 mg/gdw, while R2 LIC averages higher than R2* LIC with increasing iron load. The monoexponential-plus-constant model provided the best agreement with R2 LIC estimates.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Talassemia / Software / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Sobrecarga de Ferro / Ferro / Fígado Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Talassemia / Software / Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Sobrecarga de Ferro / Ferro / Fígado Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Child / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article