Your browser doesn't support javascript.
loading
An assessment of formaldehyde emissions from laminate flooring manufactured in China.
Pierce, Jennifer S; Abelmann, Anders; Lotter, Jason T; Ruestow, Peter S; Unice, Kenneth M; Beckett, Evan M; Fritz, Heidi A; Bare, Jennifer L; Finley, Brent L.
Afiliação
  • Pierce JS; Cardno ChemRisk, 30 North LaSalle Street Suite 3910, Chicago, IL 60602, USA. Electronic address: jennifer.pierce@cardno.com.
  • Abelmann A; Cardno ChemRisk, 30 North LaSalle Street Suite 3910, Chicago, IL 60602, USA.
  • Lotter JT; Cardno ChemRisk, 30 North LaSalle Street Suite 3910, Chicago, IL 60602, USA.
  • Ruestow PS; Cardno ChemRisk, 30 North LaSalle Street Suite 3910, Chicago, IL 60602, USA.
  • Unice KM; Cardno ChemRisk, 20 Stanwix Street Suite 505, Pittsburgh, PA 15222, USA.
  • Beckett EM; Cardno ChemRisk, 30 North LaSalle Street Suite 3910, Chicago, IL 60602, USA.
  • Fritz HA; Cardno ChemRisk, 30 North LaSalle Street Suite 3910, Chicago, IL 60602, USA.
  • Bare JL; Cardno ChemRisk, 20 Stanwix Street Suite 505, Pittsburgh, PA 15222, USA.
  • Finley BL; Cardno ChemRisk, 231 Front Street Suite 202, Brooklyn, NY 11201, USA.
Regul Toxicol Pharmacol ; 81: 20-32, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27377234
Formaldehyde emissions from two laminate flooring products, labeled as California Air Resources Board (CARB) compliant, were evaluated. Passive 24-hr samples (n = 79) and real-time measurements were collected following installation and removal of the products in two rooms of similar size. Mean formaldehyde concentrations following installation were 0.038 and 0.022 ppm for Products 1 and 2 respectively, and 7 days after flooring removal the concentrations returned to background pre-installation levels. Both products were also evaluated in a small chamber (ASTM D6007) using Deconstructive (de-laminated product) and Non-Deconstructive (intact product) methods. Deconstructive testing showed that Product 1 exceeded the applicable CARB emission standard by 4-fold, while Product 2 was equivalent to the standard. Non-Deconstructive measurements were far below the Deconstructive results and were used to predict 24-hr steady-state room air concentrations. Based on the products that we tested (one of which was found to not be compliant with the CARB standard), the airborne formaldehyde concentrations measured following installation in a real-world setting would not be expected to elicit adverse acute health effects.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Ambientais / Pisos e Cobertura de Pisos / Formaldeído / Manufaturas Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: Asia Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Poluentes Ambientais / Pisos e Cobertura de Pisos / Formaldeído / Manufaturas Tipo de estudo: Etiology_studies / Prognostic_studies / Risk_factors_studies Limite: Humans País/Região como assunto: Asia Idioma: En Ano de publicação: 2016 Tipo de documento: Article