Your browser doesn't support javascript.
loading
Evaluation of an amplicon-based next-generation sequencing panel for detection of BRCA1 and BRCA2 genetic variants.
Shin, Saeam; Hwang, In Sik; Lee, Seung-Tae; Choi, Jong Rak.
Afiliação
  • Shin S; Department of Laboratory Medicine, Hallym University College of Medicine, Seoul, Korea.
  • Hwang IS; Brain Korea 21 PLUS Project for Medical Science, Yonsei University, Seoul, Korea.
  • Lee ST; Department of Laboratory Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-752, Korea. LEE.ST@yuhs.ac.
  • Choi JR; Department of Laboratory Medicine, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, Seoul, 120-752, Korea. CJR0606@yuhs.ac.
Breast Cancer Res Treat ; 158(3): 433-40, 2016 08.
Article em En | MEDLINE | ID: mdl-27383479
ABSTRACT
The recent advances in the next-generation sequencing (NGS) technology have enabled fast, accurate, and cost-effective genetic testing. Here, we evaluated the performance of a targeted NGS panel for BRCA1/2 sequencing and confirmed its applicability in routine clinical diagnostics. We tested samples from 88 patients using the TruSeq custom panel (Illumina Inc, USA) and a MiSeq sequencer (Illumina) and compared the results to the outcomes of conventional Sanger sequencing. All 1015 sequence variations identified by Sanger sequencing were detected by NGS, except for one missense variant that might have been missed due to a rare mutation on a primer-binding site. One deletion variation, c.1909 + 12delT of BRCA2, was falsely called in all samples due to a homopolymer error. In addition, seven different single-nucleotide substitutions with low variant frequencies (range 16.2-33.3 %) were falsely called by NGS. In a separate batch, 10 different false-positive variations were found in five samples. The overall sensitivity and positive predictive value of NGS were estimated to be 99.9 and 87.5 %, respectively. The false-positive results could be excluded by setting quality and alternative allele ratio filters and/or by visual inspection using the IGV software. Targeted NGS panel for BRCA1 and BRCA2 showed an excellent agreement with Sanger sequencing results. We therefore conclude that this NGS panel can be used for routine diagnostic method in a clinical genetic laboratory.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Análise de Sequência de DNA / Proteína BRCA1 / Proteína BRCA2 / Sequenciamento de Nucleotídeos em Larga Escala Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies / Screening_studies Limite: Female / Humans País/Região como assunto: Asia Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Análise de Sequência de DNA / Proteína BRCA1 / Proteína BRCA2 / Sequenciamento de Nucleotídeos em Larga Escala Tipo de estudo: Diagnostic_studies / Evaluation_studies / Prognostic_studies / Screening_studies Limite: Female / Humans País/Região como assunto: Asia Idioma: En Ano de publicação: 2016 Tipo de documento: Article