Your browser doesn't support javascript.
loading
Molecularly imprinted macroporous monoliths for solid-phase extraction: Effect of pore size and column length on recognition properties.
Vlakh, E G; Stepanova, M A; Korneeva, Yu M; Tennikova, T B.
Afiliação
  • Vlakh EG; Institute of Macromolecular Compounds, Russian Academy of Sciences, St. Petersburg, Russia.
  • Stepanova MA; Institute of Macromolecular Compounds, Russian Academy of Sciences, St. Petersburg, Russia; Institute of Chemistry, Saint-Petersburg State University, St. Petersburg, Russia.
  • Korneeva YM; Institute of Macromolecular Compounds, Russian Academy of Sciences, St. Petersburg, Russia.
  • Tennikova TB; Institute of Macromolecular Compounds, Russian Academy of Sciences, St. Petersburg, Russia. Electronic address: tennikova@mail.ru.
J Chromatogr B Analyt Technol Biomed Life Sci ; 1029-1030: 198-204, 2016 Sep 01.
Article em En | MEDLINE | ID: mdl-27433985
The series of macroporous monolithic molecularly imprinted monoliths differed by pore size, column length (volume) and amount of template used for imprinting was synthesized using methacrylic acid and glycerol dimethacrylate as co-monomers and antibiotic ciprofloxacin as a template. The prepared monoliths were characterized regarding to their permeability, pore size, porosity, and resistance to the flow of a mobile phase. The surface morphology was also analyzed. The slight dependence of imprinting factor on flow rate, as well as its independence on pore size of macroporous molecularly imprinted monolithic media was observed. The column obtained at different conditions exhibited different affinity of ciprofloxacin to the imprinted sites that was characterized with Kdiss values in the range of 10(-5)-10(-4)M. The solid-phase extraction of ciprofloxacin from such biological liquids as human blood serum, human urine and cow milk serum was performed using the developed monolithic columns. In all cases, the extraction was found to be 95.0-98.6%. Additionally, the comparison of extraction of three fluoroqinolone analogues, e.g. ciprofloxacin, levofloxacin and moxifloxacin, from human blood plasma was carried out. Contrary to ciprofloxacin extracted with more than 95%, this parameter did not exceed 40% for its analogues.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ciprofloxacina / Extração em Fase Sólida / Impressão Molecular / Antibacterianos Limite: Animals / Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ciprofloxacina / Extração em Fase Sólida / Impressão Molecular / Antibacterianos Limite: Animals / Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article