Your browser doesn't support javascript.
loading
A new method for noninvasive venous blood oxygen detection.
Zhang, Xu; Zhang, Meimei; Zheng, Shengkun; Wang, Liqi; Ye, Jilun.
Afiliação
  • Zhang X; School of Medicine, Shenzhen University, Shenzhen, China.
  • Zhang M; National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen, China.
  • Zheng S; Guangdong Key Laboratory for Biomedical Measurements and Ultrasound Imaging, Shenzhen, China.
  • Wang L; School of Medicine, Shenzhen University, Shenzhen, China.
  • Ye J; National-Regional Key Technology Engineering Laboratory for Medical Ultrasound, Shenzhen, China.
Biomed Eng Online ; 15(1): 84, 2016 Jul 19.
Article em En | MEDLINE | ID: mdl-27436186
ABSTRACT

BACKGROUND:

Blood oxygen saturation of vein (SvO2) is an important clinical parameter for patient monitoring. However, the existing clinical methods are invasive, expensive, which are also painful for patients.

METHODS:

Based on light-absorption, this study describes a new noninvasive SvO2 measurement method by using external stimulation signal to generate cyclical fluctuation signal in the vein, which overcomes the low signal-to-noise ratio problem in the measurement process. In this way, the value of SvO2 can be obtained continuously in real time.

RESULTS:

The experimental results demonstrate that the method can successfully measure venous oxygen saturation by artificial addition of stimulation. Under hypoxic conditions, the system can reflect the overall decline of venous oxygen saturation better. When the results measured by the new method are compared with those measured by the invasive method, the root mean square error of the difference is 5.31 and the correlation coefficient of the difference is 0.72. The new method can be used to measure SvO2 and evaluate body oxygen consumption, and its accuracy needs improvement.

CONCLUSIONS:

Real-time and continuous monitoring can be achieved by replacing invasive method with noninvasive method, which provides more comprehensive clinical information in a timely manner and better meet the needs of clinical treatment. However, the accuracy of the new noninvasive SvO2 measurement based on light-absorption has to be further improved.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Veias / Gasometria / Monitorização Fisiológica Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Oxigênio / Veias / Gasometria / Monitorização Fisiológica Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article