Your browser doesn't support javascript.
loading
An isotope dilution capillary electrophoresis/tandem mass spectrometry (CE-MS/MS) method for the simultaneous measurement of choline, betaine, and dimethylglycine concentrations in human plasma.
Forteschi, Mauro; Zinellu, Angelo; Assaretti, Stefano; Mangoni, Arduino A; Pintus, Gianfranco; Carru, Ciriaco; Sotgia, Salvatore.
Afiliação
  • Forteschi M; Department of Biomedical Sciences, School of Medicine, University of Sassari, Viale San Pietro 43/B, 07100, Sassari, Italy.
  • Zinellu A; Department of Biomedical Sciences, School of Medicine, University of Sassari, Viale San Pietro 43/B, 07100, Sassari, Italy.
  • Assaretti S; Department of Biomedical Sciences, School of Medicine, University of Sassari, Viale San Pietro 43/B, 07100, Sassari, Italy.
  • Mangoni AA; Department of Clinical Pharmacology, School of Medicine, Flinders University, Bedford Park, Adelaide, South Australia, 5042, Australia.
  • Pintus G; Department of Biomedical Sciences, School of Medicine, University of Sassari, Viale San Pietro 43/B, 07100, Sassari, Italy.
  • Carru C; Department of Biomedical Sciences, School of Medicine, University of Sassari, Viale San Pietro 43/B, 07100, Sassari, Italy.
  • Sotgia S; Quality Control Unit, University Hospital Sassari (AOU), Viale San Pietro 43/B, 07100, Sassari, Italy.
Anal Bioanal Chem ; 408(26): 7505-12, 2016 Oct.
Article em En | MEDLINE | ID: mdl-27503542
ABSTRACT
Plasma concentrations of choline, betaine, and dimethylglycine provide valuable information on the flow of methyl groups in key biological processes, particularly during folate deficiency states. We developed a new method to simultaneously measure these analytes in human plasma. Following sample deproteinization using acetonitrile, an aliquot was evaporated to dryness under vacuum to be then taken up by water. Finally, analytes were separated by capillary electrophoresis and detected by electrospray ionization triple-quadrupole mass spectrometry, in multiple reaction monitoring mode, using two stable isotope-labeled internal standards. Linearity of the calibration curves of each analyte was good (R(2) > 0.99). Average limits of detection (LODs) and limits of quantification (LOQs) for choline, betaine, and dimethylglycine were, respectively, 0.43, 0.62, and 0.31 µmol/L and 1.52, 2.11, and 0.97 µmol/L. Mean recovery of three replicates of two spiked concentrations levels was close to 100 % for all of the analytes. Repeatability and intermediate precision, expressed as %RSD of measurements, were <9 %. The method, applied to measure analytes in samples from 30 patients with chronic kidney disease and 30 age- and sex-matched healthy controls, was able to detect differences between groups and the sexes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sarcosina / Betaína / Colina / Eletroforese Capilar / Espectrometria de Massas em Tandem Tipo de estudo: Evaluation_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Sarcosina / Betaína / Colina / Eletroforese Capilar / Espectrometria de Massas em Tandem Tipo de estudo: Evaluation_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article