Your browser doesn't support javascript.
loading
Cone Beam CT Versus Multislice CT: Radiologic Diagnostic Agreement in the Postoperative Assessment of Cochlear Implantation.
Razafindranaly, Victor; Truy, Eric; Pialat, Jean-Baptiste; Martinon, Amanda; Bourhis, Magali; Boublay, Nawele; Faure, Frédéric; Ltaïef-Boudrigua, Aïcha.
Afiliação
  • Razafindranaly V; *Hospices Civils de Lyon, University Hospital Edouard Herriot, Lyon †Department of Otolaryngology, pavillon U ‡Department of Radiology, pavillon B §Cellule Recherche du PAM Imagerie ||Pôle Information Médicale Evaluation Recherche, Hospices Civils de Lyon, Lyon, France.
Otol Neurotol ; 37(9): 1246-54, 2016 10.
Article em En | MEDLINE | ID: mdl-27518208
ABSTRACT

OBJECTIVE:

To evaluate the diagnostic concordance between multislice computed tomography (MSCT) and cone beam computed tomography (CBCT) in the early postoperative assessment of patients after cochlear implantation. STUDY

DESIGN:

Prospective, randomized, single-center, interventional, pilot study on the diagnostic performance of a medical device.

SETTING:

Tertiary referral center. PATIENTS Patients aged over 18 years requiring a computed tomographic (CT) scan after cochlear implant surgery.

INTERVENTIONS:

Nine patients were implanted with electrode arrays from three different manufacturers, including one bilateral. High-resolution MSCT and CBCT were then performed, and two experienced radiologists blinded to the imaging modality evaluated the randomized images, twice. MAIN OUTCOME

MEASURES:

Concordance between MSCT and CBCT for assessing the scalar position (tympani or vestibuli) of the electrodes. Secondary outcome measures were also studied length of the intracochlear electrode array, percentage of implanted cochlea, number of intracochlear electrodes, and radiation doses.

RESULTS:

There was a good agreement between both CT scanners in determining the scalar position and estimating the number of implanted electrodes and percentage of implanted cochlea. CBCT had a lower radiation exposure.

CONCLUSIONS:

The CBCT appears to be a useful tool for postoperative assessment of cochlear implanted adult patients and is comparable to the conventional scanner in determining the scalar position, with lower radiation exposure.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Cocleares / Cóclea / Implante Coclear / Tomografia Computadorizada de Feixe Cônico / Tomografia Computadorizada Multidetectores Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Implantes Cocleares / Cóclea / Implante Coclear / Tomografia Computadorizada de Feixe Cônico / Tomografia Computadorizada Multidetectores Tipo de estudo: Clinical_trials / Diagnostic_studies / Observational_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article