Optimized Protocol for Fast CT Angiography of Lower Limbs Using 160-Row Detector.
Tachibana, Adriano; Dias, Bianca Oberhuber; Failla, Bruna Bonaventura; Dos Santos Silva, Camila; Belczak, Sergio Quilici; Mendes, Cynthia de Almeida; Fioranelli, Alexandre; Wolosker, Nelson.
Afiliação
  • Tachibana A; From the *Department of Diagnostic Imaging, Hospital Israelita Albert Einstein; †Department of Vascular Surgery, Faculdade de Medicina da Universidade de São Paulo; and ‡Division of Vascular and Endovascular Surgery, Hospital Israelita Albert Einstein, São Paulo, Brazil.
J Comput Assist Tomogr ; 40(6): 953-957, 2016.
Article em En | MEDLINE | ID: mdl-27560013
ABSTRACT

OBJECTIVE:

We proposed and tested a novel acquisition protocol for optimizing a fast computed tomography angiography using a 160-row detector scanner using a longer contrast injection time coupled with multiphasic rate of injection.

METHODS:

A prospective randomized study was performed to compare image quality, contrast enhancement, and radiation dose in 2 groups (a fast acquisition and a widely accepted slow acquisition).

RESULTS:

There was no difference between groups regarding image quality, noise, and diagnostic performance, but we evidenced a trend to higher radiation dose for the fast acquisition protocol.

CONCLUSIONS:

An optimized protocol for performing a fast acquisition computed tomography angiography of lower limbs is feasible, has sufficient diagnostic quality, and can be used in selected patients who would benefit from a short-time scan.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artérias / Iohexol / Intensificação de Imagem Radiográfica / Extremidade Inferior / Tomografia Computadorizada Multidetectores / Angiografia por Tomografia Computadorizada Tipo de estudo: Clinical_trials / Diagnostic_studies / Guideline Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artérias / Iohexol / Intensificação de Imagem Radiográfica / Extremidade Inferior / Tomografia Computadorizada Multidetectores / Angiografia por Tomografia Computadorizada Tipo de estudo: Clinical_trials / Diagnostic_studies / Guideline Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2016 Tipo de documento: Article