Clinical Evaluation of 2 Point-of-Care Lateral Flow Tests for the Diagnosis of Syphilis.
Sex Transm Dis
; 43(10): 623-5, 2016 10.
Article
em En
| MEDLINE
| ID: mdl-27631356
A diagnostic performance study comparing the only Food and Drug Administration-approved, point-of-care (POC) treponemal test (Syphilis Health Check) and the World Health Organization pre-qualified SD Bioline POC treponemal test against a treponemal hemagglutination test (TPHA) and a sequential algorithm of nontreponemal rapid plasma reagin and TPHA found both POC tests had >85% sensitivity compared with the TPHA and >85% sensitivity and >95% specificity compared with the rapid plasma reagin and TPHA standards.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Treponema pallidum
/
Sífilis
/
Sistemas Automatizados de Assistência Junto ao Leito
Tipo de estudo:
Diagnostic_studies
/
Evaluation_studies
/
Guideline
/
Observational_studies
/
Prevalence_studies
/
Risk_factors_studies
Limite:
Adult
/
Female
/
Humans
/
Male
Idioma:
En
Ano de publicação:
2016
Tipo de documento:
Article