Your browser doesn't support javascript.
loading
MEASUREMENT OF INTRAOCULAR PRESSURE IN THE DOMESTIC PIGEON (COLUMBIA LIVIA).
J Zoo Wildl Med ; 47(3): 935-938, 2016 Sep.
Article em En | MEDLINE | ID: mdl-27691937
ABSTRACT
The purpose of this study was to establish intraocular pressure values in clinically normal pigeons. One hundred (52 male and 48 female) healthy pigeons ( Columbia livia ) of six different breeds, ranging in age from 20 to 51 mo were used in the study. Pigeons were gently physically restrained in a dorsoventral position without any pressure or extension to the head and neck. A rebound tonometer with a disposable probe was held horizontally and 4-5 mm from the central corneal surface. Calibration of the device was set to "P." Overall, the mean ± SD intraocular pressure values of all eyes were 6.1 ± 0.9 mmHg (ranging from 3 to 9 mmHg). Mean ± SD values for left and right eyes were 6.1 ± 1.0 and 6.0 ± 1.2 mmHg, respectively. There was no statistically significant difference in IOP between the left eye and right eye or between males and females (P = 0.49; P = 0.74). Analysis of variance revealed that there were no significant differences in the IOP between the breeds (P = 0.22).
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Columbidae / Tonometria Ocular / Pressão Intraocular Limite: Animals Idioma: En Ano de publicação: 2016 Tipo de documento: Article