Your browser doesn't support javascript.
loading
Optimization of an online heart-cutting multidimensional gas chromatography clean-up step for isotopic ratio mass spectrometry and simultaneous quadrupole mass spectrometry measurements of endogenous anabolic steroid in urine.
Casilli, Alessandro; Piper, Thomas; de Oliveira, Fábio Azamor; Padilha, Monica Costa; Pereira, Henrique Marcelo; Thevis, Mario; de Aquino Neto, Francisco Radler.
Afiliação
  • Casilli A; Brazilian Laboratory Doping Control, LBCD-LADETEC/IQ-UFRJ, Rio de Janeiro, RJ, Brazil.
  • Piper T; German Sport University Cologne, Center for Preventive Doping Research - Institute of Biochemistry, Köln, Germany.
  • de Oliveira FA; Brazilian Laboratory Doping Control, LBCD-LADETEC/IQ-UFRJ, Rio de Janeiro, RJ, Brazil.
  • Padilha MC; Brazilian Laboratory Doping Control, LBCD-LADETEC/IQ-UFRJ, Rio de Janeiro, RJ, Brazil.
  • Pereira HM; Brazilian Laboratory Doping Control, LBCD-LADETEC/IQ-UFRJ, Rio de Janeiro, RJ, Brazil.
  • Thevis M; German Sport University Cologne, Center for Preventive Doping Research - Institute of Biochemistry, Köln, Germany.
  • de Aquino Neto FR; Brazilian Laboratory Doping Control, LBCD-LADETEC/IQ-UFRJ, Rio de Janeiro, RJ, Brazil.
Drug Test Anal ; 8(11-12): 1204-1211, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27739243
ABSTRACT
Measuring carbon isotope ratios (CIRs) of urinary analytes represents a cornerstone of doping control analysis and has been particularly optimized for the detection of the misuse of endogenous steroids. Isotope ratio mass spectrometry (IRMS) of appropriate quality, however, necessitates adequate purities of the investigated steroids, which requires extensive pre-analytical sample clean-up steps due to both the natural presence of the target analytes and the high complexity of the matrix. In order to accelerate the sample preparation and increase the automation of the process, the use of multidimensional gas chromatography (MDGC) prior to IRMS experiments, was investigated. A well-established instrumental configuration based on two independent GC ovens and one heart-cutting device was optimized. The first dimension (1D) separation was obtained by a non-polar column which assured high efficiency and good loading capacity, while the second dimension (2D), based on a mid-polar stationary phase, provided good selectivity. A flame ionization detector monitored the 1D, and the 2D was simultaneously recorded by isotope ratio and quadrupole mass spectrometry. The assembled MDGC set-up was applied for measuring testosterone, 5α- and 5ß-androstanediol, androsterone, and etiocholanolone as target compounds and pregnanediol as endogenous reference compound. The urine sample were pretreated by conventional sample preparation steps comprising solid-phase extraction, hydrolysis, and liquid-liquid extraction. The extract obtained was acetylated and different aliquots were injected into the MDGC system. Two high performance liquid chromatography steps, conventionally adopted prior to CIR measurements, were replaced by the MDGC approach. The obtained values were consistent with the conventional ones. Copyright © 2016 John Wiley & Sons, Ltd.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esteroides / Testosterona / Isótopos de Carbono / Cromatografia Líquida de Alta Pressão / Etiocolanolona / Anabolizantes / Androsterona / Cromatografia Gasosa-Espectrometria de Massas Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Esteroides / Testosterona / Isótopos de Carbono / Cromatografia Líquida de Alta Pressão / Etiocolanolona / Anabolizantes / Androsterona / Cromatografia Gasosa-Espectrometria de Massas Limite: Humans Idioma: En Ano de publicação: 2016 Tipo de documento: Article