Your browser doesn't support javascript.
loading
Pelvic Beam-Hardening Artifacts in Dual-Energy CT Image Reconstructions: Occurrence and Impact on Image Quality.
Winklhofer, Sebastian; Lambert, Jack W; Sun, Yuxin; Wang, Zhen Jane; Sun, Derek S; Yeh, Benjamin M.
Afiliação
  • Winklhofer S; 1 Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Ave, Box 0628, M-372, San Francisco, CA 94143-0628.
  • Lambert JW; 2 Institute of Diagnostic and Interventional Radiology, University Hospital Zurich, University of Zurich, Zurich, Switzerland.
  • Sun Y; 1 Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Ave, Box 0628, M-372, San Francisco, CA 94143-0628.
  • Wang ZJ; 1 Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Ave, Box 0628, M-372, San Francisco, CA 94143-0628.
  • Sun DS; 1 Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Ave, Box 0628, M-372, San Francisco, CA 94143-0628.
  • Yeh BM; 1 Department of Radiology and Biomedical Imaging, University of California, San Francisco, 505 Parnassus Ave, Box 0628, M-372, San Francisco, CA 94143-0628.
AJR Am J Roentgenol ; 208(1): 114-123, 2017 Jan.
Article em En | MEDLINE | ID: mdl-27786561
ABSTRACT

OBJECTIVE:

The purpose of this study was to describe the frequency and appearance of beam-hardening artifacts on rapid-kilovoltage-switching dual-energy CT (DECT) image reconstructions of the pelvis. MATERIALS AND

METHODS:

Monochromatic (70, 52, and 120 keV) and material decomposition CT images (iodine-water and water-iodine) from consecutive pelvic rapid-kilovoltage-switching DECT scans were retrospectively evaluated. We recorded the presence, type (high versus low attenuation), and severity of beam-hardening artifacts (Likert scale from 0, barely seen, to 4, severe), clarity of anatomic delineation (Likert scale from 0, unimpaired, to 4, severely impaired) and SD of CT numbers, iodine and water concentrations, and gray-scale values for artifact-affected regions and corresponding unaffected reference tissue. A pelvic phantom was scanned and evaluated in a similar manner. Wilcoxon signed rank and paired t tests were used to compare results between the image reconstructions.

RESULTS:

Beam-hardening artifacts were seen in all image reconstructions in all 41 patients (22 men, 19 women; mean age, 57 years; range 22-86 years) who met the inclusion criteria. The median artifact severity score was worse for water-iodine and iodine-water images (score of 3 for each) than for 70-keV (score 1), 52-keV (score 2), and 120-keV (score 1) images (all p < 0.001). The anatomic delineation was worse (p < 0.001) for water-iodine and iodine-water images than for monochromatic images. Higher CT number SD values, material concentrations, and gray-scale values were found for areas affected by artifacts than for reference tissues in all datasets (all p < 0.001). Similar results were seen in the phantom study.

CONCLUSION:

Beam-hardening artifacts are prevalent in pelvic rapid-kilovoltage-switching DECT and more severe in material decomposition than monochromatic image reconstructions.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Algoritmos / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Artefatos Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pelve / Algoritmos / Interpretação de Imagem Radiográfica Assistida por Computador / Tomografia Computadorizada por Raios X / Imagem Radiográfica a Partir de Emissão de Duplo Fóton / Artefatos Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article