Serum uromodulin predicts graft failure in renal transplant recipients.
Biomarkers
; 22(2): 171-177, 2017 Mar.
Article
em En
| MEDLINE
| ID: mdl-27790922
OBJECTIVE AND METHODS: Test the ability of serum uromodulin concentrations 1-3 months after renal transplantation to predict all-cause mortality (ACM) and graft loss (GL) in 91 patients. RESULTS: uromodulin predicted GL equivalently to the other markers studied: the risk for GL was reduced by 0.21 per one standard deviation (SD) increase (cystatin C: hazard ratio [HR] 4.57, creatinine: HR 4.53, blood-urea-nitrogen [BUN]: HR 2.50, estimated glomerular filtration rate [eGFR]: HR 0.10). In receiver-operating-characteristic (ROC) analysis, uromodulin predicted GL with an area-under-the curve of 0.782 at an optimal cut-off (OCO) of 24.0 ng/ml with a sensitivity of 90.0% and a specificity of 70.2%. CONCLUSION: Serum uromodulin predicted GL equivalently compared to conventional biomarkers of glomerular filtration.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Transplante de Rim
/
Uromodulina
/
Rejeição de Enxerto
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2017
Tipo de documento:
Article