Your browser doesn't support javascript.
loading
[The first 200 transcatheter aortic valve implantations in the Gottsegen Gyorgy Institute of Cardiology, Hungary]. / Az elso 200 transzkatéteres aortabillentyu-implantáció a Gottsegen György Országos Kardiológiai Intézetben.
Fontos, Géza; Dékány, Gábor; Hegedüs, Nikolett; Piróth, Zsolt; Amit Kumar, Chaurasia; Pál, Mátyás; Mandzák, Adrienn; Takács, Viktor; Varga, Andrea; Kovács, Attila; Szabó, György; Andréka, Péter.
Afiliação
  • Fontos G; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Dékány G; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Hegedüs N; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Piróth Z; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Amit Kumar C; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Pál M; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Mandzák A; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Takács V; Medtronic Hungaria Kft. Budapest.
  • Varga A; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Kovács A; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Szabó G; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
  • Andréka P; Gottsegen György Országos Kardiológiai Intézet Budapest, Haller u. 29., 1096.
Orv Hetil ; 157(45): 1786-1792, 2016 Nov.
Article em Hu | MEDLINE | ID: mdl-27817238
ABSTRACT

INTRODUCTION:

Transcatheter aortic valve implantation is a therapeutic alternative for contraindicated and high surgical risk patients with severe symptomatic aortic stenosis. This intervention is part of daily routine in the Institute of the authors.

AIM:

In the present work the results of the first 200 patients are discussed.

METHOD:

Until January, 2016, 200 patients (female 55%, mean age 79.9 years, average EuroSCORE 19.3%, left ventricular ejection fraction 54%, peak gradient 81.2 mmHg, mean aortic gradient 50.9 mmHg) underwent transcatheter aortic valve implantation.

RESULTS:

The procedure was performed with 99% success rate. Complications were evaluated according to VARC 2 definitions. Mortality was 5% at one month and 17.4% at one year. Cardiac mortality was 13.6 at one year. Cerebrovascular complications were 5% within one year, and 95% of patients were in NYHA I or II functional classes at one year.

CONCLUSION:

These findings are consistent with worldwide results. Orv. Hetil., 2016, 157(45), 1786-1792.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: Hu Ano de publicação: 2016 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Valva Aórtica / Estenose da Valva Aórtica / Próteses Valvulares Cardíacas / Implante de Prótese de Valva Cardíaca Tipo de estudo: Diagnostic_studies Limite: Aged / Aged80 / Female / Humans / Male / Middle aged País/Região como assunto: Europa Idioma: Hu Ano de publicação: 2016 Tipo de documento: Article