Reliability of salivary cortisol and immunoglobulin-A measurements from the IPRO® before and after sprint cycling exercise.
Macdonald, Luke A; Bellinger, Phillip M; Minahan, Clare L.
Afiliação
  • Macdonald LA; Griffith University Sports Science, School of Allied Health Sciences, Griffith University, Gold Coast, Australia - luke.macdonald@griffithuni.edu.au.
  • Bellinger PM; Centre of Excellence for Applied Sport Science Research, Queensland Academy of Sport, Department of National Parks, Sport and Racing, Level 1 Queensland Sport and Athletics Centre, Nathan, Australia - luke.macdonald@griffithuni.edu.au.
  • Minahan CL; Griffith University Sports Science, School of Allied Health Sciences, Griffith University, Gold Coast, Australia.
J Sports Med Phys Fitness ; 57(12): 1680-1686, 2017 Dec.
Article em En | MEDLINE | ID: mdl-27849116
ABSTRACT

BACKGROUND:

The purpose of this study was to evaluate the inter-day reliability of the IPRO method for determining resting and postexercise salivary cortisol (sCort) and rate of salivary Immunoglobulin-A (sIgA) secretion.

METHODS:

Fourteen males (32±11 years) performed two trials (T1 and T2) separated by 7 d, comprising saliva sampling before and 15 min after completion of two, 30-s Wingate Anaerobic Tests separated by 3.5 min (2 x WAnT). sCort increased after the 2 x WAnT in both trials (T1 P<0.001; T2 P<0.001), whereas rate of sIgA secretion decreased in both trials (T1 P=0.002; T2 P=0.002).

RESULTS:

The intraclass correlation coefficients for resting and postexercise sCort and rate of sIgA secretion ranged from 0.96-0.99. Mean reliability, expressed as the coefficient of variation (%) and the typical error of measurement over the two trials were resting sCort 9.4%, 0.14 ng·mL-1 (9% CI 0.1-0.2), postexercise sCort 11.9%, 0.44 ng·mL-1 (9% CI 0.3-0.7), resting rate of sIgA secretion 7.4%, 85.5 µg·mL-1·min-1 (9% CI 65.2-127.1) and postexercise rate of sIgA secretion 10.5%, 82.9 µg·mL-1·min-1 (9% CI 63.2-123.1).

CONCLUSIONS:

The IPRO is a reliable method for determining sCort and rate of sIgA secretion at rest and after sprint-cycling exercise.