Incidence and predictors of permanent pacemaker implantation following treatment with the repositionable Lotus™ transcatheter aortic valve.
Catheter Cardiovasc Interv
; 90(1): 147-154, 2017 Jul.
Article
em En
| MEDLINE
| ID: mdl-27862860
OBJECTIVES: To determine the incidence and predictors of permanent pacemaker (PPM) requirement following transcatheter aortic valve replacement (TAVR) with the mechanically expanded LotusTM Valve System (Boston Scientific). BACKGROUND: Pacemaker implantation is the most common complication following TAVR. Predictors of pacing following TAVR with the Lotus valve have not been systematically assessed. METHODS: Consecutive patients with severe aortic stenosis who underwent Lotus valve implantation were prospectively recruited at a single-centre. Patients with a pre-existing PPM were excluded. Baseline ECG, echocardiographic and multiple detector computed tomography as well as procedural telemetry and depth of implantation were independently analyzed in a blinded manner. The primary endpoint was 30-day incidence of pacemaker requirement (PPM implantation or death while pacing-dependent). Multivariate analysis was performed to identify independent predictors of the primary endpoint. RESULTS: A total of 104 consecutive patients underwent TAVR with the Lotus valve with 9/104 (9%) with a pre-existing PPM excluded. New or worsened procedural LBBB occurred in 78%. Thirty-day incidence of the primary pacing endpoint was 28%. The most common indication for PPM implantation was complete heart block (CHB) (69%). Independent predictors of the primary endpoint included pre-existing RBBB (hazard ratio [HR] 2.8, 95% CI 1.1-7.0; P = 0.032) and depth of implantation below the noncoronary cusp (NCC) (HR 2.4, 95% CI 1.0-5.7; P = 0.045). CONCLUSIONS: Almost a third of Lotus valve recipients require pacemaker implantation within 30 days. The presence of pre-existing RBBB and the depth of prosthesis implantation below the NCC were significant pacing predictors. © 2016 Wiley Periodicals, Inc.
Palavras-chave
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Valva Aórtica
/
Estenose da Valva Aórtica
/
Marca-Passo Artificial
/
Próteses Valvulares Cardíacas
/
Estimulação Cardíaca Artificial
/
Substituição da Valva Aórtica Transcateter
/
Bloqueio Cardíaco
Tipo de estudo:
Diagnostic_studies
/
Etiology_studies
/
Incidence_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Aged80
/
Female
/
Humans
/
Male
País/Região como assunto:
Oceania
Idioma:
En
Ano de publicação:
2017
Tipo de documento:
Article