Techniques for blood volume fMRI with VASO: From low-resolution mapping towards sub-millimeter layer-dependent applications.
Huber, Laurentius; Ivanov, Dimo; Handwerker, Daniel A; Marrett, Sean; Guidi, Maria; Uludag, Kâmil; Bandettini, Peter A; Poser, Benedikt A.
Afiliação
  • Huber L; Section on Functional Imaging Methods, Laboratory of Brain and Cognition, NIMH, NIH, Bethesda, MD, USA. Electronic address: Laurentius.Huber@nih.gov.
  • Ivanov D; Maastricht Brain Imaging Centre, Faculty of Psychology and Neurosciencve, Maastricht University, Maastricht, The Netherlands.
  • Handwerker DA; Section on Functional Imaging Methods, Laboratory of Brain and Cognition, NIMH, NIH, Bethesda, MD, USA.
  • Marrett S; FMRIF, NIMH, NIH, Bethesda, MD, USA.
  • Guidi M; Max Planck Institute for Human Cognitive and Brain Sciences, Leipzig, Germany.
  • Uludag K; Maastricht Brain Imaging Centre, Faculty of Psychology and Neurosciencve, Maastricht University, Maastricht, The Netherlands.
  • Bandettini PA; Section on Functional Imaging Methods, Laboratory of Brain and Cognition, NIMH, NIH, Bethesda, MD, USA; FMRIF, NIMH, NIH, Bethesda, MD, USA.
  • Poser BA; Maastricht Brain Imaging Centre, Faculty of Psychology and Neurosciencve, Maastricht University, Maastricht, The Netherlands.
Neuroimage ; 164: 131-143, 2018 01 01.
Article em En | MEDLINE | ID: mdl-27867088
ABSTRACT
Quantitative cerebral blood volume (CBV) fMRI has the potential to overcome several specific limitations of BOLD fMRI. It provides direct physiological interpretability and promises superior localization specificity in applications of sub-millimeter resolution fMRI applications at ultra-high magnetic fields (7T and higher). Non-invasive CBV fMRI using VASO (vascular space occupancy), however, is inherently limited with respect to its data acquisition efficiency, restricting its imaging coverage and achievable spatial and temporal resolution. This limitation may be reduced with recent advanced acceleration and reconstruction strategies that allow two-dimensional acceleration, such as in simultaneous multi-slice (SMS) 2D-EPI or 3D-EPI in combination with CAIPIRINHA field-of-view shifting. In this study, we sought to determine the functional sensitivity and specificity of these readout strategies with VASO over a broad range of spatial resolutions; spanning from low spatial resolution (3mm) whole-cortex to sub-millimeter (0.75mm) slab-of-cortex (for cortical layer-dependent applications). In the thermal-noise-dominated regime of sub-millimeter resolutions, 3D-EPI-VASO provides higher temporal stability and sensitivity to detect changes in CBV compared to 2D-EPI-VASO. In this regime, 3D-EPI-VASO unveils task activation located in the cortical laminae with little contamination from surface veins, in contrast to the cortical surface weighting of GE-BOLD fMRI. In the physiological-noise-dominated regime of lower resolutions, however, 2D-SMS-VASO shows superior performance compared to 3D-EPI-VASO. Due to its superior sensitivity at a layer-dependent level, 3D-EPI VASO promises to play an important role in future neuroscientific applications of layer-dependent fMRI.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Encéfalo / Mapeamento Encefálico / Imageamento por Ressonância Magnética Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Encéfalo / Mapeamento Encefálico / Imageamento por Ressonância Magnética Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article