Your browser doesn't support javascript.
loading
Atomically Thin Graphene Windows That Enable High Contrast Electron Microscopy without a Specimen Vacuum Chamber.
Han, Yimo; Nguyen, Kayla X; Ogawa, Yui; Park, Jiwoong; Muller, David A.
Afiliação
  • Han Y; Department of Applied and Engineering Physics, Cornell University , Ithaca, New York 14853, United States.
  • Nguyen KX; Department of Chemistry and Chemical Biology, Cornell University , Ithaca, New York 14853, United States.
  • Ogawa Y; Department of Chemistry and Chemical Biology, Cornell University , Ithaca, New York 14853, United States.
  • Park J; Institute for Materials Chemistry and Engineering, Kyushu University , Kasuga, Fukuoka 816-8580, Japan.
  • Muller DA; Department of Chemistry and Chemical Biology, Cornell University , Ithaca, New York 14853, United States.
Nano Lett ; 16(12): 7427-7432, 2016 12 14.
Article em En | MEDLINE | ID: mdl-27960512
ABSTRACT
Scanning electron microscopes (SEMs) require a high vacuum environment to generate and shape an electron beam for imaging; however, the vacuum conditions greatly limit the nature of specimens that can be examined. From a purely scattering physics perspective, it is not necessary to place the specimen inside the vacuum chamber-the mean free paths (MFPs) for electron scattering in air at typical SEM beam voltages are 50-100 µm. This is the idea behind the airSEM, which removes the specimen vacuum chamber from the SEM and places the sample in air. The thickness of the gas layer is less than a MFP from an electron-transparent window to preserve the shape and resolution of the incident beam, resulting in comparable imaging quality to an all-vacuum SEM. Present silicon nitride windows scatter far more strongly than the air gap and are currently the contrast and resolution limiting factor in the airSEM. Graphene windows have been used previously to wrap or seal samples in vacuum for imaging. Here we demonstrate the use of a robust bilayer graphene window for sealing the electron optics from the room environment, providing an electron transparent window with only a 2% drop in contrast. There is a 5-fold-increase in signal/noise ratio for imaging compared to multi-MFP-thick silicon nitride windows, enabling high contrast in backscattered, transmission, and surface imaging modes for the new airSEM geometry.
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2016 Tipo de documento: Article