Your browser doesn't support javascript.
loading
1H-MR spectroscopy of suspicious breast mass lesions at 3T: a clinical experience.
Montemezzi, Stefania; Cavedon, Carlo; Camera, Lucia; Meliadò, Gabriele; Caumo, Francesca; Baglio, Ilaria; Sardanelli, Francesco.
Afiliação
  • Montemezzi S; Radiology Unit, Department of Pathology and Diagnostics, Azienda Ospedaliera Universitaria Integrata - Verona, P.le Stefani 1, 37126, Verona, Italy. stefania.montemezzi@ospedaleuniverona.it.
  • Cavedon C; Medical Physics Unit, Department of Pathology and Diagnostics, Azienda Ospedaliera Universitaria Integrata - Verona, P.le Stefani 1, 37126, Verona, Italy.
  • Camera L; Radiology Unit, Department of Pathology and Diagnostics, Azienda Ospedaliera Universitaria Integrata - Verona, P.le Stefani 1, 37126, Verona, Italy.
  • Meliadò G; Medical Physics Unit, Department of Pathology and Diagnostics, Azienda Ospedaliera Universitaria Integrata - Verona, P.le Stefani 1, 37126, Verona, Italy.
  • Caumo F; Radiology Unit, Department of Pathology and Diagnostics, Azienda Ospedaliera Universitaria Integrata - Verona, P.le Stefani 1, 37126, Verona, Italy.
  • Baglio I; Radiology Unit, Department of Pathology and Diagnostics, Azienda Ospedaliera Universitaria Integrata - Verona, P.le Stefani 1, 37126, Verona, Italy.
  • Sardanelli F; Department of Biomedical Sciences for Health, Radiology Unit, Università degli Studi di Milano, Research Hospital Policlinico San Donato, Via Morandi 30, 20097, San Donato Milanese, Milan, Italy.
Radiol Med ; 122(3): 161-170, 2017 Mar.
Article em En | MEDLINE | ID: mdl-27981485
ABSTRACT

OBJECTIVES:

To test 3T proton magnetic resonance spectroscopy (1H-MRS) for breast mass lesions.

METHODS:

Patients with BI-RADS 4-5 lesions at mammography/ultrasound were prospectively enrolled. After contrast-enhanced breast MRI, single-voxel MRS (point-resolved volume selection, PRESS); pencil-beam shimming; volume of interest 1 cm3; TR/TE = 3000/135 ms) was performed. Spectra were considered reliable if the full width at half maximum (FWHM) of the water peak was ≤45 Hz. A signal-to-noise ratio of the total choline (tCho) peak at 3.21 ppm ≥2 was used as cutoff for malignancy. All lesions underwent needle sampling. Final pathology was available for all malignant lesions; for benign lesions the reference standard was final pathology or at least 1-year negative follow-up.

RESULTS:

Reliable spectra were obtained in 115/127 lesions (91%), with a mean FWHM of 32.4 Hz (range 8-45 Hz). A tCho peak SNR ≥2 was detected in 66 malignant lesions (62 invasive cancers; 4 ductal carcinoma in situ) and in 3 benign lesions. Excluding lesions located ≤1 cm from the skin (n = 3) or pectoral muscle (n = 11), sensitivity was 65/73 [89%, 95% confidence interval (CI) 80-95%], and specificity 25/28 (89%) (95% CI 72-98%). Considering only invasive cancers, sensitivity reached 61/68 (90%, 95% CI 81-96%). MRS additional time was 8 min.

CONCLUSIONS:

When lesions close to the skin or pectoral muscle are excluded, 3T 1H-MRS of mass lesions ≥1 cm showed a high diagnostic performance, however, insufficient to avoid needle biopsy.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Espectroscopia de Prótons por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Espectroscopia de Prótons por Ressonância Magnética Tipo de estudo: Diagnostic_studies / Observational_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article