Your browser doesn't support javascript.
loading
Diagnostic accuracy of contemporary multidetector computed tomography (MDCT) for the detection of lumbar disc herniation.
Notohamiprodjo, S; Stahl, R; Braunagel, M; Kazmierczak, P M; Thierfelder, K M; Treitl, K M; Wirth, S; Notohamiprodjo, M.
Afiliação
  • Notohamiprodjo S; Institute for Clinical Radiology, University Hospital of Munich, LMU Munich, Nussbaumstr. 20, 80336, Munich, Germany. Susan.Notohamiprodjo@med.lmu.de.
  • Stahl R; Institute for Clinical Radiology, University Hospital of Munich, LMU Munich, Nussbaumstr. 20, 80336, Munich, Germany.
  • Braunagel M; Institute for Clinical Radiology, University Hospital of Munich, LMU Munich, Nussbaumstr. 20, 80336, Munich, Germany.
  • Kazmierczak PM; Institute for Clinical Radiology, University Hospital of Munich, LMU Munich, Nussbaumstr. 20, 80336, Munich, Germany.
  • Thierfelder KM; Institute for Clinical Radiology, University Hospital of Munich, LMU Munich, Nussbaumstr. 20, 80336, Munich, Germany.
  • Treitl KM; Institute for Clinical Radiology, University Hospital of Munich, LMU Munich, Nussbaumstr. 20, 80336, Munich, Germany.
  • Wirth S; Institute for Clinical Radiology, University Hospital of Munich, LMU Munich, Nussbaumstr. 20, 80336, Munich, Germany.
  • Notohamiprodjo M; Diagnostic and Interventional Radiology, University Hospital Tübingen, Eberhard Karls University Tübingen, Tübingen, Germany.
Eur Radiol ; 27(8): 3443-3451, 2017 Aug.
Article em En | MEDLINE | ID: mdl-27988890
ABSTRACT

OBJECTIVES:

To evaluate the diagnostic accuracy of multidetector CT (MDCT) for detection of lumbar disc herniation with MRI as standard of reference.

METHODS:

Patients with low back pain underwent indicated MDCT (128-row MDCT, helical pitch), 60 patients with iterative reconstruction (IR) and 67 patients with filtered back projection (FBP). Lumbar spine MRI (1.5 T) was performed within 1 month. Signal-to-noise ratios (SNR) of cerebrospinal fluid (CSF), annulus fibrosus (AF) and the spinal cord (SC) were determined for all modalities. Two readers independently rated image quality (IQ), diagnostic confidence and accuracy in the diagnosis of lumbar disc herniation using MRI as standard of reference. Inter-reader correlation was assessed with weighted κ.

RESULTS:

Sensitivity, specificity, precision and accuracy of MDCT for disc protrusion were 98.8%, 96.5%, 97.1%, 97.8% (disc level), 97.7%, 92.9%, 98.6%, 96.9% (patient level). SNR of IR was significantly higher than FBP. IQ was significantly better in IR owing to visually reduced noise and improved delineation of the discs. κ (>0.90) was excellent for both algorithms.

CONCLUSION:

MDCT of the lumbar spine yields high diagnostic accuracy for detection of lumbar disc herniation. IR improves image quality so that the provided diagnostic accuracy is principally equivalent to MRI. KEY POINTS • MDCT is an accurate alternative to MRI in disc herniation diagnosis. • By IR enhanced image quality improves MDCT diagnostic confidence similar to MRI. • Advances in CT technology contribute to improved diagnostic performance in lumbar spine imaging.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Deslocamento do Disco Intervertebral / Vértebras Lombares Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Deslocamento do Disco Intervertebral / Vértebras Lombares Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies / Observational_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article