Your browser doesn't support javascript.
loading
Characterisation of rollator use using inertial sensors.
Cheng, Tsu-Jui; Kenney, Laurence; Amor, James David; Thies, Sibylle Brunhilde; Costamagna, Eleonora; James, Christopher; Holloway, Catherine.
Afiliação
  • Cheng TJ; Centre for Health Sciences Research , University of Salford , Salford M6 6PU , UK.
  • Kenney L; Centre for Health Sciences Research , University of Salford , Salford M6 6PU , UK.
  • Amor JD; Warwick Engineering in Biomedicine, School of Engineering , University of Warwick , Coventry CV4 7AL , UK.
  • Thies SB; Centre for Health Sciences Research , University of Salford , Salford M6 6PU , UK.
  • Costamagna E; Centre for Health Sciences Research , University of Salford , Salford M6 6PU , UK.
  • James C; Warwick Engineering in Biomedicine, School of Engineering , University of Warwick , Coventry CV4 7AL , UK.
  • Holloway C; Department of Computer Science , University College London , Gower Street, London WC1E 6BT , UK.
Healthc Technol Lett ; 3(4): 303-309, 2016 Dec.
Article em En | MEDLINE | ID: mdl-28008367
ABSTRACT
The use of walking aids is prevalent among older people and people with mobility impairment. Rollators are designed to support outdoor mobility and require the user to negotiate curbs and slopes in the urban environment. Despite the prevalence of rollators, analysis of their use outside of controlled environments has received relatively little attention. This Letter reports on an initial study to characterise rollator movement. An inertial measurement unit (IMU) was used to measure the motion of the rollator and analytical approaches were developed to extract features characterising the rollator movement, properties of the surface and push events. The analytics were tested in two situations first, a healthy participant used a rollator in a laboratory using a motion capture system to obtain ground truth. Second, the IMU was used to measure the movement of a rollator being used by a user with multiple sclerosis on a flat surface, cross-slope, up and down slopes and up and down a step. The results showed that surface inclination and distance travelled measured by the IMU have close approximation to the results from ground truth; therefore, demonstrating the potential for IMU-derived metrics to characterise rollator movement and user's pushing style in the outdoor environment.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Risk_factors_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article