Hypoglycaemia misdiagnosed by capillary glucose measurement.
Lee, K O; Wong, J E; Cheah, J S.
Afiliação
  • Lee KO; Department of Medicine, National University Hospital.
Ann Acad Med Singap ; 18(4): 453-5, 1989 Jul.
Article em En | MEDLINE | ID: mdl-2802508
ABSTRACT
The diagnosis of hypoglycaemia has become much easier with the introduction of bedside capillary glucose measurements which require a single drop of blood from a finger prick. However, such a diagnosis may be wrongly made in patients with poor peripheral circulation. This case report illustrates the common circumstances where misdiagnosis occurs A drop of venous blood should be used for bedside glucose measurement if the diagnosis is in doubt.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Glicemia / Hipoglicemia Limite: Aged / Female / Humans Idioma: En Ano de publicação: 1989 Tipo de documento: Article