Portico Sheathless Transcatheter Aortic Valve Implantation via Distal Axillary Artery.
Bruschi, Giuseppe; Colombo, Paola; Botta, Luca; Nava, Stefano; Merlanti, Bruno; Belli, Oriana; Musca, Francesco; Soriano, Francesco; Russo, Claudio F; Oliva, Fabrizio.
Afiliação
  • Bruschi G; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy. Electronic address: giuseppe.bruschi@fastwebnet.it.
  • Colombo P; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
  • Botta L; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
  • Nava S; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
  • Merlanti B; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
  • Belli O; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
  • Musca F; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
  • Soriano F; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
  • Russo CF; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
  • Oliva F; "De Gasperis" Cardiac Center, ASST Niguarda General Hospital, Milan, Italy.
Ann Thorac Surg ; 103(2): e175-e177, 2017 Feb.
Article em En | MEDLINE | ID: mdl-28109383
ABSTRACT
Transcatheter aortic valve implantation has been designed to treat older patients affected by severe aortic stenosis who are considered high-risk surgical candidates because of multiple comorbidities. The least invasive approach for transcatheter aortic valves implantation should be considered the transfemoral retrograde route, because it is minimally invasive and is feasible with local anesthesia and mild sedation. Despite significant technical improvements in recent years, the transfemoral approach is contraindicated in cases of severe peripheral artery disease. We describe the first case of a Portico transcatheter aortic valve implantation system (St. Jude Medical, Minneapolis, MN) made through the distal axillary artery in a 90-year-old patient affected by severe aortic stenosis.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Desenho de Prótese / Imageamento Tridimensional / Substituição da Valva Aórtica Transcateter / Angiografia por Tomografia Computadorizada Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged80 / Female / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Estenose da Valva Aórtica / Desenho de Prótese / Imageamento Tridimensional / Substituição da Valva Aórtica Transcateter / Angiografia por Tomografia Computadorizada Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Aged80 / Female / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article