Your browser doesn't support javascript.
loading
Automated Algorithm for Detection of Transient Adenosine Release.
Borman, Ryan P; Wang, Ying; Nguyen, Michael D; Ganesana, Mallikarjunarao; Lee, Scott T; Venton, B Jill.
Afiliação
  • Borman RP; Department of Chemistry, University of Virginia , Charlottesville, Virginia 22904, United States.
  • Wang Y; Department of Chemistry, University of Virginia , Charlottesville, Virginia 22904, United States.
  • Nguyen MD; Department of Chemistry, University of Virginia , Charlottesville, Virginia 22904, United States.
  • Ganesana M; Department of Chemistry, University of Virginia , Charlottesville, Virginia 22904, United States.
  • Lee ST; Department of Chemistry, University of Virginia , Charlottesville, Virginia 22904, United States.
  • Venton BJ; Department of Chemistry, University of Virginia , Charlottesville, Virginia 22904, United States.
ACS Chem Neurosci ; 8(2): 386-393, 2017 02 15.
Article em En | MEDLINE | ID: mdl-28196418
ABSTRACT
Spontaneous adenosine release events have been discovered in the brain that last only a few seconds. The identification of these adenosine events from fast-scan cyclic voltammetry (FSCV) data is difficult due to the random nature of adenosine release. In this study, we develop an algorithm that automatically identifies and characterizes adenosine transient features, including event time, concentration, and duration. Automating the data analysis reduces analysis time from 10 to 18 h to about 40 min per experiment. The algorithm identifies adenosine based on its two oxidation peaks, the time delay between them, and their current vs time peak ratios. In order to validate the program, four data sets from three independent researchers were analyzed by the algorithm and then compared to manual identification by an analyst. The algorithm resulted in 10 ± 4% false negatives and 9 ± 3% false positives. The specificity of the algorithm was verified by comparing calibration data for adenosine triphosphate (ATP), histamine, hydrogen peroxide, and pH changes and these analytes were not identified as adenosine. Stimulated histamine release in vivo was also not identified as adenosine. The code is modular in design and could be easily adjusted to detect features of spontaneous dopamine or other neurochemical transients in FSCV data.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento Eletrônico de Dados / Adenosina / Córtex Pré-Frontal Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Algoritmos / Processamento Eletrônico de Dados / Adenosina / Córtex Pré-Frontal Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2017 Tipo de documento: Article