Your browser doesn't support javascript.
loading
Evaluation of a multi-atlas CT synthesis approach for MRI-only radiotherapy treatment planning.
Guerreiro, F; Burgos, N; Dunlop, A; Wong, K; Petkar, I; Nutting, C; Harrington, K; Bhide, S; Newbold, K; Dearnaley, D; deSouza, N M; Morgan, V A; McClelland, J; Nill, S; Cardoso, M J; Ourselin, S; Oelfke, U; Knopf, A C.
Afiliação
  • Guerreiro F; Faculty of Sciences, University of Lisbon, Campo Grande, Portugal; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom. Electronic address: filipaguerreiro23@gmail.com.
  • Burgos N; Translational Imaging Group, Centre for Medical Imaging Computing, University College London, London, United Kingdom. Electronic address: n.burgos@ucl.ac.uk.
  • Dunlop A; Royal Marsden Hospital, London, United Kingdom.
  • Wong K; Royal Marsden Hospital, London, United Kingdom.
  • Petkar I; Royal Marsden Hospital, London, United Kingdom.
  • Nutting C; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Royal Marsden Hospital, London, United Kingdom.
  • Harrington K; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Royal Marsden Hospital, London, United Kingdom.
  • Bhide S; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Royal Marsden Hospital, London, United Kingdom.
  • Newbold K; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Royal Marsden Hospital, London, United Kingdom.
  • Dearnaley D; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Royal Marsden Hospital, London, United Kingdom.
  • deSouza NM; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Royal Marsden Hospital, London, United Kingdom.
  • Morgan VA; Royal Marsden Hospital, London, United Kingdom.
  • McClelland J; Centre for Medical Image Computing, Dept. Medical Physics and Biomedical Engineering, University College London, London, United Kingdom.
  • Nill S; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom.
  • Cardoso MJ; Translational Imaging Group, Centre for Medical Imaging Computing, University College London, London, United Kingdom.
  • Ourselin S; Translational Imaging Group, Centre for Medical Imaging Computing, University College London, London, United Kingdom.
  • Oelfke U; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom; Royal Marsden Hospital, London, United Kingdom.
  • Knopf AC; Division of Radiotherapy and Imaging, The Institute of Cancer Research, London, United Kingdom.
Phys Med ; 35: 7-17, 2017 Mar.
Article em En | MEDLINE | ID: mdl-28242137
ABSTRACT
BACKGROUND AND

PURPOSE:

Computed tomography (CT) imaging is the current gold standard for radiotherapy treatment planning (RTP). The establishment of a magnetic resonance imaging (MRI) only RTP workflow requires the generation of a synthetic CT (sCT) for dose calculation. This study evaluates the feasibility of using a multi-atlas sCT synthesis approach (sCTa) for head and neck and prostate patients. MATERIAL AND

METHODS:

The multi-atlas method was based on pairs of non-rigidly aligned MR and CT images. The sCTa was obtained by registering the MRI atlases to the patient's MRI and by fusing the mapped atlases according to morphological similarity to the patient. For comparison, a bulk density assignment approach (sCTbda) was also evaluated. The sCTbda was obtained by assigning density values to MRI tissue classes (air, bone and soft-tissue). After evaluating the synthesis accuracy of the sCTs (mean absolute error), sCT-based delineations were geometrically compared to the CT-based delineations. Clinical plans were re-calculated on both sCTs and a dose-volume histogram and a gamma analysis was performed using the CT dose as ground truth.

RESULTS:

Results showed that both sCTs were suitable to perform clinical dose calculations with mean dose differences less than 1% for both the planning target volume and the organs at risk. However, only the sCTa provided an accurate and automatic delineation of bone.

CONCLUSIONS:

Combining MR delineations with our multi-atlas CT synthesis method could enable MRI-only treatment planning and thus improve the dosimetric and geometric accuracy of the treatment, and reduce the number of imaging procedures.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Atlas como Assunto / Planejamento da Radioterapia Assistida por Computador / Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X Tipo de estudo: Evaluation_studies / Observational_studies / Risk_factors_studies Limite: Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Atlas como Assunto / Planejamento da Radioterapia Assistida por Computador / Imageamento por Ressonância Magnética / Tomografia Computadorizada por Raios X Tipo de estudo: Evaluation_studies / Observational_studies / Risk_factors_studies Limite: Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article