Your browser doesn't support javascript.
loading
Enhanced Fluorescence ELISA Based on HAT Triggering Fluorescence "Turn-on" with Enzyme-Antibody Dual Labeled AuNP Probes for Ultrasensitive Detection of AFP and HBsAg.
Wu, Yudong; Guo, Weisheng; Peng, Weipan; Zhao, Qian; Piao, Jiafang; Zhang, Bo; Wu, Xiaoli; Wang, Hanjie; Gong, Xiaoqun; Chang, Jin.
Afiliação
  • Wu Y; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
  • Guo W; CAS Key Laboratory for Biological Effects of Nanomaterials & Nanosafety National Center for Nanoscience and Technology , Beijing 100190, China.
  • Peng W; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
  • Zhao Q; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
  • Piao J; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
  • Zhang B; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
  • Wu X; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
  • Wang H; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
  • Gong X; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
  • Chang J; School of Materials Science and Engineering, School of Life Sciences, Tianjin University and Tianjin Engineering Center of Micro-Nano Biomaterials and Detection-Treatment Technology (Tianjin) , 92 Weijin Road, Nankai District, Tianjin 300072, P. R. China.
ACS Appl Mater Interfaces ; 9(11): 9369-9377, 2017 Mar 22.
Article em En | MEDLINE | ID: mdl-28252291
At present, enzyme-linked immunosorbent assay (ELISA) is considered to be the most appropriate approach in clinical biomarker detection, with good specificity, low cost, and straightforward readout. However, unsatisfactory sensitivity severely hampers its wide application in clinical diagnosis. Herein, we designed a new kind of enhanced fluorescence enzyme-linked immunosorbent assay (FELISA) based on the human alpha-thrombin (HAT) triggering fluorescence "turn-on" signals. In this system, detection antibodies (Ab2) and HAT were labeled on the gold nanoparticles (AuNPs) to form the detection probes, and a bisamide derivative of Rhodamine110 with fluorescence quenched served as the substrate of HAT. After the sandwich immunoreaction, HAT on the sandwich structure could catalyze the cleavage of the fluorescence-quenched substrate, leading to a strong fluorescence signal for sensing ultralow levels of alpha fetoprotein (AFP) and hepatitis B virus surface antigen (HBsAg). Under the optimized reaction conditions, AFP and HBsAg were detected at the ultralow concentrations of 10-8 ng mL-1 and 5 × 10-4 IU mL-1, respectively, which were at least 104 times lower than those of the conventional fluorescence assay and 106 times lower than those of the conventional ELISA. In addition, we further discussed the efficiency of the sensitive FELISA in clinical serum samples, showing great potential in practical applications.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio de Imunoadsorção Enzimática Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ensaio de Imunoadsorção Enzimática Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article