Your browser doesn't support javascript.
loading
Development of a paper-based microfluidic analytical device by a more facile hydrophobic substrate generation strategy.
Xue, Yuan-Yuan; Zhang, Wen-Tao; Zhang, Meng-Yue; Liu, Li-Zhi; Zhu, Wen-Xin; Yan, Ling-Zhi; Wang, Jing; Wang, Yan-Ru; Wang, Jian-Long; Zhang, Dao-Hong.
Afiliação
  • Xue YY; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Zhang WT; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Zhang MY; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Liu LZ; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Zhu WX; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Yan LZ; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Wang J; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Wang YR; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China.
  • Wang JL; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China. Electronic address: wanglong79@nwsuaf.edu.cn.
  • Zhang DH; College of Food Science and Engineering, Northwest A&F University, Yangling 712100, Shaanxi, China. Electronic address: zhangdh@nwsuaf.edu.cn.
Anal Biochem ; 525: 100-106, 2017 05 15.
Article em En | MEDLINE | ID: mdl-28263739
ABSTRACT
Microfluidic paper-based analytical devices (µPADs) have a significant potential in developing portable and disposable point-of-care testing (POCT). Herein, a facile, rapid, cost-effective and environment friendly strategy for µPADs fabrication is proposed. Specifically, the substrate paper was hydrophobized by coating with trimethoxysilane (TOS), and then the selected area was hydrophilized by treating with surfactant. The whole fabrication process was implemented within 7 min, with no need for complex pre-treatment, high-temperature and special equipment. As a proof-of-concept application, the as-prepared µPAD was applied to determination of the glucose content in human serum samples. The results agreed well with those obtained by a glucometer. We believe that the µPADs fabrication method proposed here could provide a facile, rapid and low-cost reference for other related studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Glicemia / Técnicas Analíticas Microfluídicas Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papel / Glicemia / Técnicas Analíticas Microfluídicas Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article