Inter- and intra-observer variability of ultrasonographic arm muscle thickness measurement by critical care physicians.
Hadda, V; Kumar, R; Dhungana, A; Khan, M A; Madan, K; Khilnani, G C.
Afiliação
  • Hadda V; Department of Pulmonary Medicine and Sleep Disorders, All Institute of Medical Sciences, New Delhi, India.
  • Kumar R; Department of Pulmonary Medicine and Sleep Disorders, All Institute of Medical Sciences, New Delhi, India.
  • Dhungana A; Department of Pulmonary Medicine and Sleep Disorders, All Institute of Medical Sciences, New Delhi, India.
  • Khan MA; Department of Biostatistics, All Institute of Medical Sciences, New Delhi, India.
  • Madan K; Department of Pulmonary Medicine and Sleep Disorders, All Institute of Medical Sciences, New Delhi, India.
  • Khilnani GC; Department of Pulmonary Medicine and Sleep Disorders, All Institute of Medical Sciences, New Delhi, India.
J Postgrad Med ; 63(3): 157-161, 2017.
Article em En | MEDLINE | ID: mdl-28272064
ABSTRACT

PURPOSE:

The aim of this study was to assess inter- and intra-observer variability of arm muscle thickness measured by critical care physicians using bedside ultrasonography (USG).

METHODOLOGY:

This prospective study included twenty patients admitted with sepsis. Three measurements of thickness of right arm muscles of each patient using B-mode USG were taken by two critical care fellows, independently. Intra- and inter-observer reliability was tested using intraclass correlation coefficient (ICC).

RESULTS:

The mean 1st, 2nd, and 3rd measurements of muscle thickness recorded by observer 1 and 2 were 23.620 (±4.171) versus 23.840 (±3.849) mm, 23.235 (±3.620) versus 23.625 (±4.062) mm, and 24.125 (±4.098) versus 23.965 (±3.651) mm, respectively. The average muscle thickness measured by first and second observer was 23.660 (±3.834) mm and 23.810 (±3.674) mm, respectively. ICC for intra-observer variability for observer 1 and 2 was 0.964 (95% confidence interval [CI] 0.924-0.985) and 0.949 (95% CI 0.892-0.978), respectively. ICC for inter-observer variability was 0.995 (95% CI 0.988-0.998).

CONCLUSIONS:

USG is a reliable tool for assessment of arm muscle thickness by critical care physicians.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Médicos / Braço / Ultrassonografia / Sepse / Unidades de Terapia Intensiva Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Médicos / Braço / Ultrassonografia / Sepse / Unidades de Terapia Intensiva Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article