Your browser doesn't support javascript.
loading
Angioscopic and optical coherence tomographic evaluation of neointimal coverage: 9 months after expandable polyterafluoroethylene covered stent implantation.
Kongoji, Ken; Ishibashi, Yuki; Kotoku, Nozomi; Kasahara, Mizuho; Yamazaki, Hiroshi; Mitarai, Takanobu; Kamijima, Ryo; Koyama, Kohei; Yoneyama, Kihei; Tanabe, Yasuhiro; Akashi, Yoshihiro J.
Afiliação
  • Kongoji K; Division of Cardiology, Department of Internal Medicine, Kyorin University School of Medicine, 6-20-2, Shinkawa, Mitaka City, Tokyo, 181-8611, Japan. kkongoji@ks.kyorin-u.ac.jp.
  • Ishibashi Y; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Kotoku N; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Kasahara M; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Yamazaki H; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Mitarai T; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, Yokohama, Japan.
  • Kamijima R; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Koyama K; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Yokohama City Seibu Hospital, Yokohama, Japan.
  • Yoneyama K; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Tanabe Y; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan.
  • Akashi YJ; Division of Cardiology, Department of Internal Medicine, St. Marianna University School of Medicine, Kawasaki, Japan.
Heart Vessels ; 32(6): 777-779, 2017 Jun.
Article em En | MEDLINE | ID: mdl-28289840
ABSTRACT
An expandable polytetrafluoroethylene (ePTFE) covered stent is generally employed to seal coronary artery perforation. The frequency of ePTFE covered stent use is relatively low; thus, only a handful of studies have reported neointimal coverage and endothelialization inside the deployed ePTFE and clinical time course after ePTFE implantation. This case report presents a 78-year-old man treated with an ePTFE covered stent when he suffered from coronary artery perforation after the implantation of two everolimus eluting stents in the left anterior descending artery. Follow-up coronary angiography 9 months after ePTFE covered stent implantation depicted favorable stent patency. Optical coherence tomography showed thin and uneven stent strut coverage at the culprit. Angioscopy also depicted partial white-coated coverage and stent strut exposure. The outcome of this case suggested that long-term dual antiplatelet therapy should be prescribed for preventing thrombosis after ePTFE covered stent implantation.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Vasos Coronários / Stents Farmacológicos / Neointima Limite: Aged / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Angioplastia Coronária com Balão / Vasos Coronários / Stents Farmacológicos / Neointima Limite: Aged / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article