Your browser doesn't support javascript.
loading
The early variation of left ventricular twisting function in patients with lymphoma received anthracycline therapy assessed by three-dimensional speckle tracking echocardiography.
Song, Feiyan; Kang, Yu; Zhang, Chujie; Xu, Yuchen; Shi, Jing; Guo, Ye; Zhang, Qunling; Shu, Xianhong; Cheng, Leilei.
Afiliação
  • Cheng L; Department of Echocardiography, Zhongshan Hospital, Fudan University, Shanghai Institute of Cardiovascular Diseases, Shanghai Institute of Medical Imaging, Shanghai, China. cheng.leilei@zs-hospital.sh.cn.
Cardiol J ; 24(5): 484-494, 2017.
Article em En | MEDLINE | ID: mdl-28353310
ABSTRACT

BACKGROUND:

Anthracycline-induced cardiotoxicity remains a significant and unresolved issue in patients receiving chemotherapy. The aim of this study was to evaluate left ventricular (LV) twisting function by three-dimensional speckle tracking echocardiography (3D-STE) in patients with lymphoma after anthracycline therapy.

METHODS:

One hundred and one patients with newly diagnosed diffuse large B-cell lymphoma who had planned to receive anthracycline chemotherapy were enrolled. LV apical rotation, basal rotation, twist, torsion, time to peak apical rotation and time to peak basal rotation were measured by 3D-STE at baseline, after the completion of two cycles and four cycles of the regimen, respectively. Apical-basal rotation delay was calculated as the difference between time to basal and time to apical rotation.

RESULTS:

The results showed that LV apical rotation, basal rotation, twist and torsion declined progressively during the whole procedure (baseline vs. two and four cycles of the regimen, apical rotation 12.5 ± ± 4.5° vs. 8.8 ± 3.6° vs. 6.0 ± 3.2°; basal rotation -7.7 ± 3.0° vs. -5.9 ± 2.6° vs. -4.4 ± 2.5°; twist 20.0 ± 6.4° vs. 14.5 ± 5.1° vs. 9.8 ± 4.5°; torsion 2.9 ± 0.9°/cm vs. 2.1 ± 0.9°/cm vs. 1.4 ± 0.7°/cm; all p < 0.01). Furthermore, apical-basal rotation delay increased significantly after two cycles as well as after four cycles of the regimen (38.3 ± 67.9 ms vs. 66.7 ± 73.9 ms vs. 92.6 ± 96.9 ms; p < 0.01).

CONCLUSIONS:

LV twisting function deteriorated in the early stage of anthracycline therapy in patients with lymphoma, which could be detected by 3D-STE sensitively.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Anormalidade Torcional / Função Ventricular Esquerda / Linfoma Difuso de Grandes Células B / Disfunção Ventricular Esquerda / Ecocardiografia Doppler de Pulso / Antraciclinas / Ecocardiografia Tridimensional / Antibióticos Antineoplásicos Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Anormalidade Torcional / Função Ventricular Esquerda / Linfoma Difuso de Grandes Células B / Disfunção Ventricular Esquerda / Ecocardiografia Doppler de Pulso / Antraciclinas / Ecocardiografia Tridimensional / Antibióticos Antineoplásicos Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article