Your browser doesn't support javascript.
loading
New protocol based on massive parallel sequencing for aneuploidy screening of preimplantation human embryos.
Vendrell, Xavier; Fernández-Pedrosa, Victoria; Triviño, Juan Carlos; Bautista-Llácer, Rosa; Collado, Carmen; Rodríguez, Oscar; García-Mengual, Elena; Ferrer, Empar; Calatayud, Carmen; Ruiz-Jorro, Miguel.
Afiliação
  • Vendrell X; a Reproductive Genetics Unit , Sistemas Genómicos Ltd. , Paterna , Valencia , Spain.
  • Fernández-Pedrosa V; b Next-Generation Sequencing Laboratory , Sistemas Genómicos Ltd. , Paterna , Valencia , Spain.
  • Triviño JC; c Bioinformatics Department , Sistemas Genómicos Ltd. , Paterna , Valencia , Spain.
  • Bautista-Llácer R; a Reproductive Genetics Unit , Sistemas Genómicos Ltd. , Paterna , Valencia , Spain.
  • Collado C; b Next-Generation Sequencing Laboratory , Sistemas Genómicos Ltd. , Paterna , Valencia , Spain.
  • Rodríguez O; c Bioinformatics Department , Sistemas Genómicos Ltd. , Paterna , Valencia , Spain.
  • García-Mengual E; a Reproductive Genetics Unit , Sistemas Genómicos Ltd. , Paterna , Valencia , Spain.
  • Ferrer E; d CREA Reproductive Medicine Center , Valencia , Spain.
  • Calatayud C; d CREA Reproductive Medicine Center , Valencia , Spain.
  • Ruiz-Jorro M; d CREA Reproductive Medicine Center , Valencia , Spain.
Syst Biol Reprod Med ; 63(3): 162-178, 2017 Jun.
Article em En | MEDLINE | ID: mdl-28394645
ABSTRACT
Novel next-generation sequencing procedures have rapidly emerged into the preimplantation genetic screening framework. This work presents the design and validation of a new low-coverage whole-genome sequencing assay for aneuploidy detection in single blastomeres and trophectodermal samples from preimplantation embryos. The validation ensures analytical sensitivity, specificity, robustness, precision, limit of detection, resolution, and reproducibility. Specific parameters to measure the performance are defined, and the results are compared with a standardized array-based method to stablish the concordance. From the single cell genomics point of view, the main novelties are the length of reads of the libraries (150 nucleotides) together with a paired-end strategy and the design of an original algorithm and copy number viewer. A total of 129 samples were included in six experimental runs using a MiSeq Illumina platform. Samples included single amniocytes, single blastomeres (cleavage-stage embryos), trophectoderm samples (blastocyst), and diluted DNA. Sensitivity and specificity were calculated per chromosome yielding 96% and 99%, respectively. The percentage of concordant samples was 98.2% and all of the aneuploid samples were confirmed. In conclusion, the validation yields highly reliable and reproducible results, representing an accurate and cost-effective strategy for the routine detection of aneuploidy in human embryos.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico Pré-Implantação Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Diagnóstico Pré-Implantação Tipo de estudo: Diagnostic_studies / Screening_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article