Your browser doesn't support javascript.
loading
A novel method of self-pulling and latter transected delta-shaped Billroth-I anastomosis in totally laparoscopic distal gastrectomy.
Hong, Jun; Wang, Ya-Ping; Wang, Jian; Bei, Yi-Bing; Hua, Lu-Chun; Hao, Han-Kun.
Afiliação
  • Hong J; Department of General Surgery, Huashan Hospital, Fudan University, 12 Wulumuqi Middle Road, Shanghai, 200040, China.
  • Wang YP; Department of General Surgery, Huashan Hospital, Fudan University, 12 Wulumuqi Middle Road, Shanghai, 200040, China.
  • Wang J; Department of General Surgery, Huashan Hospital, Fudan University, 12 Wulumuqi Middle Road, Shanghai, 200040, China.
  • Bei YB; Department of General Surgery, Huashan Hospital, Fudan University, 12 Wulumuqi Middle Road, Shanghai, 200040, China.
  • Hua LC; Department of General Surgery, Huashan Hospital, Fudan University, 12 Wulumuqi Middle Road, Shanghai, 200040, China.
  • Hao HK; Department of General Surgery, Huashan Hospital, Fudan University, 12 Wulumuqi Middle Road, Shanghai, 200040, China. hhk_hs@hotmail.com.
Surg Endosc ; 31(11): 4831, 2017 11.
Article em En | MEDLINE | ID: mdl-28409373
ABSTRACT

BACKGROUND:

We developed a modified delta-shaped gastroduodenostomy technique in totally laparoscopic distal gastrectomy. This novel technique, which effectively reduces the required quantity of linear stapler [1-3], was named as self-pulling and latter transected delta-shaped anastomosis (Delta SPLT) [4].

METHODS:

Delta SPLT was performed on 15 patients with stage cT1-2 antral cancer. We ligated the duodenum with a rope instead of transecting it and used the ligature rope to pull the duodenum during the whole progress of gastroduodenostomy. When closing the entry hole, the duodenum was transected at the same time, which saved one linear stapler. Data of clinicopathologic characteristics, surgical and postoperative outcomes were collected and expressed as means ± standard deviations.

RESULTS:

All the operations were successfully performed by using no more than four 60-mm linear staplers. The mean BMI of the patients is 23.0 ± 2.5 kg/m2 (range 17.0-26.0 kg/m2), and duration of the operation was 115.0 ± 33.4 min (range 75-215 min), including 22.3 ± 6.7 min (range 15-35 min) of reconstruction. Mean blood loss was 82.7 ± 71.3 mL (range 10-300 mL), and mean times to first flatus was 2.3 ± 1.1 days (range 1-5 days). A mean number of 27.5 ± 5.4 (range 18-38) lymph nodes was retrieved. Overall postoperative morbidity rate was 6.7% (1/15). There was no anastomosis-related complication, but one case of pneumonia developed on postoperative day (POD) 2 which was successfully managed by conservative methods. Patients were discharged (POD mean 5.8 ± 1.3, range 4-9) when their bowel movements recovered and no discomfort with soft diet was claimed.

CONCLUSION:

Delta SPLT is a safe and feasible technique and requires less clinical costs.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Gástricas / Gastroenterostomia / Laparoscopia Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Gástricas / Gastroenterostomia / Laparoscopia Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article