Your browser doesn't support javascript.
loading
Effects of RF pulse profile and intra-voxel phase dispersion on MR fingerprinting with balanced SSFP readout.
Chiu, Su-Chin; Lin, Te-Ming; Lin, Jyh-Miin; Chung, Hsiao-Wen; Ko, Cheng-Wen; Büchert, Martin; Bock, Michael.
Afiliação
  • Chiu SC; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan; Medical Physics, Department of Radiology, University Medical Center Freiburg, Freiburg, Germany.
  • Lin TM; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan; Department of Radiology, Taipei Veterans General Hospital, Taipei, Taiwan.
  • Lin JM; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan; Department of Radiology, University of Cambridge, Cambridge, United Kingdom.
  • Chung HW; Graduate Institute of Biomedical Electronics and Bioinformatics, National Taiwan University, Taipei, Taiwan. Electronic address: chunghw@ntu.edu.tw.
  • Ko CW; Department of Computer Science and Engineering, National Sun Yat-Sen University, Kaohsiung, Taiwan.
  • Büchert M; Medical Physics, Department of Radiology, University Medical Center Freiburg, Freiburg, Germany.
  • Bock M; Medical Physics, Department of Radiology, University Medical Center Freiburg, Freiburg, Germany.
Magn Reson Imaging ; 41: 80-86, 2017 09.
Article em En | MEDLINE | ID: mdl-28412455
ABSTRACT

PURPOSE:

To investigate possible errors in T1 and T2 quantification via MR fingerprinting with balanced steady-state free precession readout in the presence of intra-voxel phase dispersion and RF pulse profile imperfections, using computer simulations based on Bloch equations. MATERIALS AND

METHODS:

A pulse sequence with TR changing in a Perlin noise pattern and a nearly sinusoidal pattern of flip angle following an initial 180-degree inversion pulse was employed. Gaussian distributions of off-resonance frequency were assumed for intra-voxel phase dispersion effects. Slice profiles of sinc-shaped RF pulses were computed to investigate flip angle profile influences. Following identification of the best fit between the acquisition signals and those established in the dictionary based on known parameters, estimation errors were reported. In vivo experiments were performed at 3T to examine the results.

RESULTS:

Slight intra-voxel phase dispersion with standard deviations from 1 to 3Hz resulted in prominent T2 under-estimations, particularly at large T2 values. T1 and off-resonance frequencies were relatively unaffected. Slice profile imperfections led to under-estimations of T1, which became greater as regional off-resonance frequencies increased, but could be corrected by including slice profile effects in the dictionary. Results from brain imaging experiments in vivo agreed with the simulation results qualitatively.

CONCLUSION:

MR fingerprinting using balanced SSFP readout in the presence of intra-voxel phase dispersion and imperfect slice profile leads to inaccuracies in quantitative estimations of the relaxation times.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ondas de Rádio / Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética Tipo de estudo: Prognostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Ondas de Rádio / Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética Tipo de estudo: Prognostic_studies Limite: Adult / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article