Your browser doesn't support javascript.
loading
Validity and Reliability of a Portable Isometric Mid-Thigh Clean Pull.
James, Lachlan P; Roberts, Llion A; Haff, G Gregory; Kelly, Vincent G; Beckman, Emma M.
Afiliação
  • James LP; 1School of Human Movement and Nutrition Sciences, University of Queensland, Queensland, Australia;2Center for Sport and Exercise Science Research, Edith Cowan University, Perth, Australia; and3Brisbane Broncos Rugby League Football Club, Queensland, Australia.
J Strength Cond Res ; 31(5): 1378-1386, 2017 May.
Article em En | MEDLINE | ID: mdl-28415068
ABSTRACT
James, LP, Roberts, LA, Haff, GG, Kelly, VG, and Beckman, EM. Validity and reliability of a portable isometric mid-thigh clean pull. J Strength Cond Res 31(5) 1378-1386, 2017-This study investigated the test-retest reliability and criterion validity of force-time curve variables collected through a portable isometric mid-thigh clean pull (IMTP) device equipped with a single-axial load cell. Fifteen males with ≥6 months of resistance training experience attended two testing sessions. In each session, participants performed an IMTP in 2 separate conditions in a randomized counterbalanced manner. The criterion condition consisted of a closed-chain IMTP configured with a force plate (IMTPf), whereas the experimental test was undertaken using a portable IMTP with data acquired through a single-axial load cell (IMTPl). A very high reliability (coefficient of variation [CV] = 3.10, 90% confidence interval [CI] 2.4-4.6%; intraclass correlation coefficient [ICC] = 0.96, 90% CI 0.90-0.98) and acceptable validity (CV = 9.2, 90% CI 7-14%; ICC = 0.88, 90% CI 0.71-0.95) were found in the experimental condition for the measure of peak force. However, significant differences were present between the IMTPf and IMTPl (p < 0.0001). Alternate force-time curve variables did not reach acceptable levels of validity or reliability in the experimental condition. The IMTPl is a valid and highly reliable method for assessing peak force. This provides evidence supporting the use of an IMTPl as a cost-effective and portable alternative for those who wish to assess maximal force production in a similar fashion to a traditional IMTP. However, practitioners should be aware that these are slightly different tests.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coxa da Perna / Teste de Esforço / Força Muscular / Treinamento Resistido / Contração Isométrica Tipo de estudo: Clinical_trials Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coxa da Perna / Teste de Esforço / Força Muscular / Treinamento Resistido / Contração Isométrica Tipo de estudo: Clinical_trials Limite: Adult / Humans / Male Idioma: En Ano de publicação: 2017 Tipo de documento: Article