Your browser doesn't support javascript.
loading
Atrium Advanta V12 Large Diameter Stent-Graft Applications for Infrarenal Abdominal Aortic Pseudoaneurysms (due to Behcet Disease): Safety and Efficacy.
Altay, Çetin Murat; Alpar, Ayhan; Topcuoglu, Osman Melih; Kucukay, Murat Bulent; Cansu, Dondu Uskudar; Temel, Tuncer; Ozbulbul, Nilgun Isiksalan; Kucukay, Fahrettin.
Afiliação
  • Altay ÇM; Department of Radiology, Keciören Research and Training Hospital, Ankara, Turkey.
  • Alpar A; Department of Radiology, Sancaktepe Bolge Hastanesi, Istanbul, Turkey.
  • Topcuoglu OM; Department of Interventional Radiology, Faculty of Medicine, Yeditepe University, Istanbul, Turkey.
  • Kucukay MB; Department of Internal Medicine, Ozel Lokman Hekim Hospital, Ankara, Turkey.
  • Cansu DU; Department of Rheumatology, Faculty of Medicine, Osmangazi University, Eskisehir, Turkey.
  • Temel T; Department of Gastroenterology, Faculty of Medicine, Osmangazi University, Eskisehir, Turkey.
  • Ozbulbul NI; Department of Radiology, Faculty of Medicine, Osmangazi University, Eskisehir, Turkey.
  • Kucukay F; Department of Interventional Radiology, Faculty of Medicine, Osmangazi University, Eskisehir, Turkey. Electronic address: fkucukay@hotmail.com.
Ann Vasc Surg ; 44: 197-202, 2017 Oct.
Article em En | MEDLINE | ID: mdl-28479445
BACKGROUND: The aim of the study was to determine the safety and effectiveness of Atrium Advanta V12 large diameter stent-graft applications for infrarenal abdominal aortic pseudoaneurysms (due to Behcet disease [BD]). METHODS: Data of Advanta V12™ (Atrium Europe B.V, Mijdrecht, the Netherlands) applied 12 female patients (mean age 30.5 ± 6.3, range 26-44) with infrarenal abdominal aortic pseudoaneurysms were analyzed retrospectively. All Advanta V12 large diameter stent grafts were implemented from right or left sided 12F femoral sheaths. Stent grafts with 12-16 mm in size and 29-61 mm in length were utilized. Technical success rate, procedure-related mortality and morbidity, and primary patency rate at 4 years were evaluated. RESULTS: Technical success rate was 100%. Neither procedure-related mortality nor morbidity was determined. The mean aortic diameter was 14.0 ± 0.8 mm for pseudoaneurysmatic abdominal aortas. The mean follow-up period was 46.5 ± 40.3 months (range 18-75). During follow-ups, only one recurrent aneurysm has evolved at the stenting site due to patients' withdrawal of immunosuppressive treatment. The advent of a new aneurysm proximal or distal to the stent-graft region or at the femoral access localization was not observed. There were no stent occlusions. Primary patency rate at 4 years was 100%. Complete aneurysm exclusion was achieved 100% at 48 months. CONCLUSIONS: The use of Advanta V12 large diameter stent grafts for infrarenal abdominal aortic pseudoaneurysms (due to BD), especially in female patients with small aortic diameter, is safe and efficient. Primary patency rate of the stent grafts at 4 years is excellent.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Síndrome de Behçet / Aneurisma da Aorta Abdominal / Falso Aneurisma / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Prótese Vascular / Stents / Síndrome de Behçet / Aneurisma da Aorta Abdominal / Falso Aneurisma / Implante de Prótese Vascular / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article