Your browser doesn't support javascript.
loading
Low-Cost Device for Fluorescein-Guided Surgery in Malignant Brain Tumor.
Lovato, Renan Maximilian; Vitorino Araujo, João Luiz; Esteves Veiga, José Carlos.
Afiliação
  • Lovato RM; Division of Neurosurgery, Department of Surgery, Santa Casa de São Paulo School of Medical Sciences, São Paulo, São Paulo, Brazil. Electronic address: renan_lovato@yahoo.com.br.
  • Vitorino Araujo JL; Division of Neurosurgery, Department of Surgery, Santa Casa de São Paulo School of Medical Sciences, São Paulo, São Paulo, Brazil; Arnaldo Vieira de Carvalho Cancer Institute, Oncocenter, Hospital Nove de Julho, Hospital Bandeirantes, and Hospital Israelita Albert Einstein, São Paulo, São Paulo, Brazil.
  • Esteves Veiga JC; Division of Neurosurgery, Department of Surgery, Santa Casa de São Paulo School of Medical Sciences, São Paulo, São Paulo, Brazil.
World Neurosurg ; 104: 61-67, 2017 Aug.
Article em En | MEDLINE | ID: mdl-28483673
BACKGROUND: Gross total resection for malignant brain neoplasms is challenging owing to the heterogeneity of these lesions and infiltration in eloquent areas. Gross total resection is a very important part of treatment of these patients and is a crucial prognostic factor. Fluorescence-guided surgery is an important tool that improves the rate of total resection. METHODS: We built a device to use in surgical microscopes with an excitation and a barrier filter to perform fluorescence-guided surgery. All patients received a standard dose of 500 mg of sodium fluorescein before skin incision. Surgical view under white light was compared with use of the light filters. RESULTS: In all cases with use of the filters, the tumors showed a high fluorescence contrasting with the normal surrounding brain, making it easier to identify the limits of the lesion and to achieve gross total resection. CONCLUSIONS: The use of fluorescence for malignant brain tumor resection increases the rate of gross total resection. It is an important tool that makes it possible to identify the lesion in areas where it looks like normal tissue under white light. This device is a low-cost option that has shown good results in our experience.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Fluoresceína / Cirurgia Assistida por Computador / Microscopia de Fluorescência Tipo de estudo: Diagnostic_studies / Health_economic_evaluation / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias Encefálicas / Fluoresceína / Cirurgia Assistida por Computador / Microscopia de Fluorescência Tipo de estudo: Diagnostic_studies / Health_economic_evaluation / Prognostic_studies Limite: Aged / Female / Humans / Male / Middle aged País/Região como assunto: America do sul / Brasil Idioma: En Ano de publicação: 2017 Tipo de documento: Article