Your browser doesn't support javascript.
loading
Efficacy and safety of non-invasive body tightening with high-intensity focused ultrasound (HIFU).
Ko, E J; Hong, J Y; Kwon, T-R; Choi, E J; Jang, Y-J; Choi, S Y; Yoo, K H; Kim, S Y; Kim, B J.
Afiliação
  • Ko EJ; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, South Korea.
  • Hong JY; Department of Dermatology, Myongji Hospital, Seonam University College of Medicine, Goyang, Korea.
  • Kwon TR; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, South Korea.
  • Choi EJ; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, South Korea.
  • Jang YJ; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, South Korea.
  • Choi SY; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, South Korea.
  • Yoo KH; Department of Medicine, Graduate School, Chung-Ang University, Seoul, Korea.
  • Kim SY; Department of Dermatology, Chung-Ang University College of Medicine, Seoul, South Korea.
  • Kim BJ; Department of Dermatology, Seoul Paik Hospital, Inje University College of Medicine, Seoul, Korea.
Skin Res Technol ; 23(4): 558-562, 2017 Nov.
Article em En | MEDLINE | ID: mdl-28543777
ABSTRACT

BACKGROUND:

Noninvasive skin-tightening devices have become increasingly popular in response to increasing demand for improvements in skin laxity and tightening with minimal risk and recovery time.

OBJECTIVE:

We evaluated the efficacy and safety of HIFU for skin tightening in the face and body.

METHODS:

A total of 32 Korean subjects enrolled in this prospective clinical trial. The subjects were treated with HIFU to both cheeks, lower abdomen, and thigh. Skin elasticity was measured before and after treatment using a Cutometer (CT575, Courage and Khazaka® , Cologne, Germany). Three blinded, experienced dermatologists evaluated paired pre- and post-treatment (week 4 and 12) photographs according to the Global Aesthetic Improvement Scale (GAIS). Participants also completed self-assessments using GAIS. Subjects rated their pain on a numeric rating scale (NRS) immediately, 7 days, 4 weeks, and 12 weeks after treatment.

RESULTS:

Skin elasticity measured via a Cutometer was significantly improved 12 weeks after treatment at all treated sites (P<.05). Both IGAIS and SGAIS showed significant improvements 12 weeks after treatment. Immediately after treatment the mean NRS score was 3.00±1.586, but no pain was reported at 4 and 12 weeks post-treatment. No serious adverse effects were observed during the follow-up period.

CONCLUSION:

HIFU safely and effectively improves skin elasticity and clinical contouring of the face and body.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Envelhecimento da Pele / Ablação por Ultrassom Focalizado de Alta Intensidade / Contorno Corporal Tipo de estudo: Etiology_studies / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Envelhecimento da Pele / Ablação por Ultrassom Focalizado de Alta Intensidade / Contorno Corporal Tipo de estudo: Etiology_studies / Observational_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2017 Tipo de documento: Article