Combined Angiography and Late Gadolinium Enhancement Acquisition to Improve Assessment of Pulmonary Vein Isolation for Atrial Fibrillation.
Lam, Adrian; Okene, Erica; Parikh, Ankit; Zhong, Xiaodong; Tejada, Thor; Hoskins, Michael; Lloyd, Michael; Oshinski, John N.
Afiliação
  • Lam A; Wallace H. Coulter Department of Biomedical Engineering, Georgia Institute of Technology, Atlanta, Georgia, USA.
  • Okene E; Department of Medicine, Division of Cardiology, Emory University, Atlanta, Georgia, USA.
  • Parikh A; Department of Medicine, Division of Cardiology, Emory University, Atlanta, Georgia, USA.
  • Zhong X; MR R&D Collaborations, Siemens Healthcare, Atlanta, Georgia, USA.
  • Tejada T; Department of Radiology and Imaging Sciences, Emory University, Atlanta, Georgia, USA.
  • Hoskins M; Department of Medicine, Division of Cardiology, Emory University, Atlanta, Georgia, USA.
  • Lloyd M; Department of Medicine, Division of Cardiology, Emory University, Atlanta, Georgia, USA.
  • Oshinski JN; Department of Medicine, Division of Cardiology, Emory University, Atlanta, Georgia, USA.
J Magn Reson Imaging ; 47(2): 477-486, 2018 02.
Article em En | MEDLINE | ID: mdl-28556294
ABSTRACT

PURPOSE:

To develop a Shared K-space (SharK) magnetic resonance imaging (MRI) sequence that combines angiographic and late gadolinium enhancement (LGE) acquisitions to improve atrial wall segmentation and scar identification, and to develop a novel visualization method that quantifies scar encirclement of pulmonary veins postablation treatment for atrial fibrillation. MATERIALS AND

METHODS:

A SharK sequence was developed and used at 3T to image the left atrium in 11 patients postcryoballoon ablation. The effects of sharing k-space between the angiographic and LGE acquisitions on the accuracy of scar were assessed. The left atrial wall was segmented and points about each pulmonary vein (PV) ostia were projected onto a bullseye to quantitatively compare PV encirclement. The parameters used to quantify encirclement were varied to perform a sensitivity analysis.

RESULTS:

Compared to using a complete set of k-space, total atrial scar differences were significant only when sharing >75% k-space (P = 0.014), and 90% sensitivity and specificity for identifying scar was achieved when sharing 50% k-space. In patients, the right PVs showed more intersubject variance in encirclement compared to the left PVs. A 100° anteroinferior portion of the left PVs was always encircled, while the superior segments of both right PVs was ablated in only 6/11 patients.

CONCLUSION:

A SharK sequence was developed to combine angiographic and LGE imaging for atrial wall segmentation and scar identification. The PV bullseye quantifies and localizes encirclement about the PVs. The left PVs showed a higher amount of scar encirclement and less variability compared to the right PVs. LEVEL OF EVIDENCE 2 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2018;47477-486.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Aumento da Imagem / Angiografia por Ressonância Magnética / Meios de Contraste / Gadolínio Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Veias Pulmonares / Fibrilação Atrial / Aumento da Imagem / Angiografia por Ressonância Magnética / Meios de Contraste / Gadolínio Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Ano de publicação: 2018 Tipo de documento: Article