Your browser doesn't support javascript.
loading
Determination of nitrate in biological fluids by HPLC.
Ashraf, Muhammad; Ghalloo, Bilal Ahmed; Hayat, Muhammad Munawar; Rahman, Jameel; Ejaz, Samina; Iqbal, Muhammad; -Nasim, Faizul Hassan.
Afiliação
  • Ashraf M; Department of Chemistry, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
  • Ghalloo BA; Department of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
  • Hayat MM; Department of Pharmacy, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
  • Rahman J; Department of Chemistry, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
  • Ejaz S; Department of Biochemistry and Biotechnology, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
  • Iqbal M; Department of Biochemistry and Biotechnology, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
  • -Nasim FH; Department of Chemistry, The Islamia University of Bahawalpur, Bahawalpur, Pakistan.
Pak J Pharm Sci ; 30(1): 135-142, 2017 Jan.
Article em En | MEDLINE | ID: mdl-28603123
ABSTRACT
Nitrate is the stable product of nitric oxide, which is physiologically active radical, an immunomodulator and a neuromodulator; its quantification in biological fluids is important to study the physiological and biochemical nature. Therefore, the purpose of this study was to quantify nitrate in different biological fluids like serum, cerebrospinal fluid (CSF) and ascetic fluid (ASF) using HPLC technique. A new HPLC method for the estimation of nitrate in serum, CSF and ASF was developed using the mobile phase of 1.0mM each of Na2CO3 and NaHCO3 (11, v/v, pH 5 with H3PO4) at a flow rate of 1.0mLmin-1. Eluate was detected at 220nm with the retention time of nitrate 2.55 min. The LOD and LOQ values of nitrate were 0.03µgmL-1 and 0.098µgmL-1, respectively. Nitrate was eluted through SAX Hypersil column of 150 × 4.6mm, id, 5µm particle size. Run time was 10min. The method was validated according to the FDA guidelines and was found linear in the range of 0.39 to 50µgmL-1 and CV was <3%, within limits of FDA guidelines. The method was used successfully for the estimation of nitrate in biological fluids like serum, CSF and ASF of 20 patients each. This is an alternate and reproducible method for the detection of nitrates in biological fluids.
Assuntos
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Líquido Ascítico / Cromatografia Líquida de Alta Pressão / Nitratos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Líquido Ascítico / Cromatografia Líquida de Alta Pressão / Nitratos Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2017 Tipo de documento: Article