Ag Nanoparticles Drop-Casting Modification of Screen-Printed Electrodes for the Simultaneous Voltammetric Determination of Cu(II) and Pb(II).
Pérez-Ràfols, Clara; Bastos-Arrieta, Julio; Serrano, Núria; Díaz-Cruz, José Manuel; Ariño, Cristina; de Pablo, Joan; Esteban, Miquel.
Afiliação
  • Pérez-Ràfols C; Departament d'Enginyeria Química i Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain. claraperezrafols@ub.edu.
  • Bastos-Arrieta J; Departament d'Enginyeria Química, Universitat Politècnica de Catalunya (UPC), Campus Diagonal Besòs, Edificio I (EEBE), Carrer Eduard Maristany 10-14, 08019 Barcelona, Spain. julio.bastos@upc.edu.
  • Serrano N; Barcelona Research Center for Multiscale Science and Engineering, 08019 Barcelona, Spain. julio.bastos@upc.edu.
  • Díaz-Cruz JM; Departament d'Enginyeria Química i Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain. nuria.serrano@ub.edu.
  • Ariño C; Departament d'Enginyeria Química i Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain. josemanuel.diaz@ub.edu.
  • de Pablo J; Departament d'Enginyeria Química i Química Analítica, Facultat de Química, Universitat de Barcelona, Martí i Franquès 1-11, 08028 Barcelona, Spain. cristina.arino@ub.edu.
  • Esteban M; Departament d'Enginyeria Química, Universitat Politècnica de Catalunya (UPC), Campus Diagonal Besòs, Edificio I (EEBE), Carrer Eduard Maristany 10-14, 08019 Barcelona, Spain. joan.de.pablo@upc.edu.
Sensors (Basel) ; 17(6)2017 Jun 21.
Article em En | MEDLINE | ID: mdl-28635631
ABSTRACT
A new silver nanoparticle modified screen-printed electrode was developed and applied to the simultaneous determination of Pb(II) and Cu(II). Two different types of silver nanoparticles with different shapes and sizes, Ag nanoseeds and Ag nanoprisms, were microscopically characterized and three different carbon substrates, graphite, graphene and carbon nanofibers, were tested. The best analytical performance was achieved for the combination of Ag nanoseeds with a carbon nanofiber modified screen-printed electrode. The resulting sensor allowed the simultaneous determination of Pb(II) and Cu(II) at trace levels and its applicability to natural samples was successfully tested with a groundwater certified reference material, presenting high reproducibility and trueness.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Ano de publicação: 2017 Tipo de documento: Article