Your browser doesn't support javascript.
loading
Investigation of Noise and Contrast Sensitivity of an Electron Multiplying Charge-Coupled Device (EMCCD) based Cone Beam Micro-CT System.
Krishnakumar, Sumukh Bysani; Podgorsak, Alexander R; Nagesh, Sv Setlur; Jain, Amit; Rudin, Stephen; Bednarek, Daniel R; Ionita, Ciprian N.
Afiliação
  • Krishnakumar SB; Department of Biomedical Engineering, State University of New York at Buffalo.
  • Podgorsak AR; Toshiba Stroke and Vascular Research Center, Buffalo, NY.
  • Nagesh SS; Department of Biomedical Engineering, State University of New York at Buffalo.
  • Jain A; Toshiba Stroke and Vascular Research Center, Buffalo, NY.
  • Rudin S; Toshiba Stroke and Vascular Research Center, Buffalo, NY.
  • Bednarek DR; Toshiba Stroke and Vascular Research Center, Buffalo, NY.
  • Ionita CN; Department of Biomedical Engineering, State University of New York at Buffalo.
Proc SPIE Int Soc Opt Eng ; 97832016 Feb 27.
Article em En | MEDLINE | ID: mdl-28638172
ABSTRACT
A small animal micro-CT system was built using an EMCCD detectors having complex pre-digitization amplification technology, high-resolution, high-sensitivity and low-noise. Noise in CBCT reconstructed images when using pre-digitization amplification behaves differently than commonly used detectors and warrants a detailed investigation. In this study, noise power and contrast sensitivity were estimated for the newly built system. Noise analysis was performed by scanning a water phantom. Tube voltage was lowered to minimum delivered by the tube (20 kVp and 0.5 mA) and detector gain was varied. Contrast sensitivity was analyzed by using a phantom containing different iodine contrast solutions (20% to 70%) filled in six different tubes. First, we scanned the phantom using various x-ray exposures at 40 kVp while changing the gain to maintain the background air value of the projection images constant. Next, the exposure was varied while the detector gain was maintained constant. Radial NPS plots show that noise power level increases as gain increases. Contrast sensitivity was analyzed by calculating ratio of signal-to-noise ratios (SNR) for increased gain with those of low constant gain at each exposure. The SNR value at low constant gain was always lower than SNR of high detector gain at all x-ray settings and iodine contrast. The largest increase of SNR approached 1.3 for low contrast feature for an iodine concentration of 20%. Despite an increase in noise level as gain increases, the SNR improvement shows that signal level also increases because of the unique on-chip gain of the detector.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2016 Tipo de documento: Article